Maintaining & Servicing Appliance; Quick Reference Maintenance Guide - Quadra-Fire 21M-ACC Owner's Manual

2100 millennium wood; advanced combustion control (acc)
Hide thumbs Also See for 21M-ACC:
Table of Contents

Advertisement

R
9
Maintaining & Servicing Your Appliance
A. Quick Reference Maintenance Guide
BAFFLE & BLANKET PLACEMENT
Baffle and blanket placement is critical to heat out-
put, efficiency and overall life of the unit. Make sure
the baffle is pushed all of the way to the back of the
firebox and the blanket is laying flat.
CHIMNEY & CAP INSPECTION
The chimney and chimney
cap must be inspected for
soot and creosote during
the burn season. This will
prevent pipe blockage, poor
draft, and chimney fires.
Always burn dry wood to
help prevent cap blockage
and creosote build-up.
Start the first inspection of your unit af-
ter the first 2 months of use, or if perfor-
mance changes, and adjust your sched-
ule accordingly.
May 5, 2011
2100 Millennium Wood Stove (ACC)
INSPECT FIREBRICKS & ASH GRATE
(AFTER EACH CLEANING)
Step Top Models Only
Firebrick is designed to protect your firebox. Replace
firebricks that are crumbling, cracked or broken. If
you have an optional ash door, check to make sure
the door is closing properly.
DOOR & LATCH CHECK
Check the door latch for proper adjustment. This
is very important especially after the door rope has
formed to the stove face.
Maintenance is required for safe oper-
ation and must be performed to main-
tain your warranty.
7039-131H
2
2
Keeping the door and glass
gasket in good shape will
maintain good burn times on
a low burn setting.
Check the glass frame for
loose screws to prevent air
leakage.
Page 27

Advertisement

Table of Contents
loading

This manual is also suitable for:

2100 millennium

Table of Contents