Section 1 0 : Troub Les Hooting - Quadra-Fire Isle Royale 823-0170-MBK Owner's Manual

Non-catalytic, top-load, wood heater installation and operation
Hide thumbs Also See for Isle Royale 823-0170-MBK:
Table of Contents

Advertisement

1 0
W ith proper installation, operation, and maintenance your woodstove will provide years of trouble- free service. If you do
experience a problem, this troubleshooting guide will assist you or a qualified service person in the diagnosis of a problem
and the corrective action to be tak e n.
Start F ire P rob lems
Can not get fire started
E x cessive smok e or spillage
B urns too slowly
Not enough heat output
F ire burns too fast
M arch 2 1 , 2 0 1 3
Is le Royale Wood Stov e
Troub les hooting G uide
P os s ib le Caus e
Not enough k indling/paper or no
k indling/paper
Not enough air for fire to ignite
W ood condition is too wet, too
large
B ed of coals not established
before adding wood
F lue block age such as birds'
nests or leaves in termination
cap
Down draft or negative pressure
C ompetition with ex haust
devices
E x tremely dry or soft wood
O verdrafting
Solution
Use dry kindling, more paper. Arrange kindling &
wood for air movement.
C heck for restricted termination cap
C heck for block age of outside air k it ( if installed) .
Check for flue blockage.
Pre-warm flue before starting fire (refer to Building
a F ire Section) .
C heck for adeq uate vent height ( refer to C himney
H eight Section) .
O pen window below the appliance towards the
wind.
U se dry, seasoned wood ( refer to Seasoned W ood
Section) .
Start with paper & k indling to establish bed of
coals ( refer to B uilding a F ire Section) .
H ave chimney inspected for creosote and cleaned
by a certified chimney sweep.
Do not use ex haust fans during start- up ( refer to
Negative P ressure Section) .
O pen window below the appliance towards the
wind.
M ix in hardwood.
Mix in less seasoned wood after fire is established
( refer to W ood F uel Section) .
Check for correct vent height; too much vertical
height creates overdrafting.
C heck location of vent termination ( refer to
C himney T ermination Req uirement Section) .
2 5 0 - 5 7 6 3 F
R
P age 3 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Isle royale 823-0290-pmh