Min. Chimney Clearance to
Wall Spacer and
Combustibles - 2 inch (51mm)
Chimney Flue
Liner
Fireclay
Liner or
Equivalent
Masonry Chimney
Constructed to NFPA 211
F igure 1 6 . 1 - Solid P ack Chimney with Metal Supports
as a Thimb le ( Cont' d)
Chimney Height / Ris e and Run
T his product was designed for and tested on a 6 inch
( 1 5 2 mm) chimney, 1 2 to 1 4 feet ( 4 2 0 - 4 8 0 cm) high, ( includes
stove height) measured from the base of the appliance to
the the top of the chimney ( not including chimney cap) .
T he further your stack height or diameter varies from this
configuration, the possibility of performance problems exists.
C himney height may need to be increased by 2 - 3 %
each 1 0 0 0 feet above sea level. It is not recommended to
use offsets or elbows at altitudes above 4 0 0 0 feet above sea
level or when there are other factors that affect flue draft.
WARNING
F ire Ris k .
Inspection of C himney:
Chimney must be in good condition.
Meets minimum standard of NFPA 211
Factory-built chimney must be 6 inch
(152mm) UL103 HT.
WARNING
As phyx iation Ris k .
DO NOT CONNECT THIS UNIT TO A CHIM-
NEY FLUE SERVICING ANOTHER APPLI-
ANCE.
• DO NOT CONNECT TO ANY AIR DISTRIBU-
TION DUCT OR SYSTEM.
May allow flue gases to enter the house.
P age 1 6
R
Is le Royale Wood Stov e
Min. Clearance
2 inch (51mm)
1 inch (25mm) Air
Space to Chimney
Section
Chimney
Connector
Chimney Section
Trim Collar
Wall Band
Wall Spacer
Mas onry Chimney Liner
F or optimal performance, masonry chimneys used to vent
this appliance should be:
1. Lined with a 6 inch (152mm) stainless steel liner.
• Installations into a clay flue without a stainless steel
liner may reduce draw which affects performance,
cause the glass to dark e n and produce ex c e ssive
creosote.
2 . It is recommended that a chimney with a larger diameter
than 6 inches ( 1 5 2 mm) be relined.
• The oversized flue can cause poor performance and
contribute to the accumulation of creosote.
3 . H ave the chimney cleaned before the stove is installed
and operated.
T he following bullets list the more critical req uirements for a
properly constructed chimney:
• T he masonry wall of the chimney, if brick or modular
block , must be a minimum of 4 inches ( 1 0 2 mm) nominal
thick n ess.
• A chimney of rubble stone must be at least 12 inches
( 3 0 5 mm) thick .
• The chimney must have a fire clay flue liner (or equivalent)
per
with a minimum thick n ess of 5 /8 inch ( 1 6 mm) and must
be installed with refractory mortar.
• An equivalent liner must be a listed chimney liner system
or other approved material.
• Since an oversized flue contributes to the accumulation
of creosote, the size of the flue should be checked to
determine that it is not too large for the insert.
• T he chimney should also be check ed to ensure it meets
the minimum standard of the National F ire P rotection
Association (NFPA) Standard 211.
• A chimney support package must be used when a
connection is made through the ceiling to a factory built
chimney.
• An approved thimble and chimney support package
are ab s olutely neces s ary to provide safe clearances to
combustible wall and ceiling material.
NOTICE : In C anada, the installation shall conform to
CAN/CSA-B365.
NOTIC E : C hec k with your local building authorities
and/or consult the National Fire Protection Association
(NFPA 211).