This manual contains instructions for Installation, Operation & Maintenance. Please read this entire manual
before you install and use your new room heater. Failure to follow instructions may result in property
damage, bodily injury, or even death.
1) When installing your stove, particular attention should be paid to fire protection. If this room heater is not properly installed,
a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building, fire officials
or authority having jurisdiction about restrictions, installation inspection and permit requirements in your area.
2) CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or
"freshen up" a fire in this heater. Keep all such liquids well away from the heater while it is in use.
3) During operation, if any part of the stove starts to glow, the stove is in an overfired condition. Close the air controls
completely by pulling them out, until the glowing has stopped. OVERFIRING VOIDS YOUR WARRANTY!
4) Cool ashes should be disposed of carefully, using a metal container.
5) Do not burn wet or green wood. Store wood in a dry location.
6) DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. Do not
burn treated wood, or wood with salt (driftwood, etc.). Burning materials other than wood (including charcoal) under
adverse conditions may generate carbon monoxide in the home, resulting in illness or possible death.
7) Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.
8) Check your chimney system thoroughly when installing into an existing metal or masonry chimney. Seek professional
advice if in doubt about its condition.
9) Do not connect this unit to a chimnney flue already serving another appliance.
10) Comply with all minimum clearances to combustibles as shown in this manual for this appliance.
11) Build fire on brick firebox floor. Do not use grates, andirons or other methods to support fuel.
12) HOT WHILE IN OPERATION! Keep children, pets, clothing and furniture away. Contact can cause skin burns.
13) Do not connect to any air distribution duct or system.
14) RISK OF FIRE! Do not operate with stove door or ash removal system door open.
15) For further information refer to NFPA 211 (US) or CAN/CSA-B365 (Canada).
16) Do not operate without fully assembling all components. Burning your stove wthout the legs attached (if supplied with
unit) will void your warranty, and could present a serious safety hazard.
17) Do not operate with broken glass.
PRIOR TO FIRST FIRE: Remove all labels from glass. Clean all plated surfaces with a glass cleanser and soft cloth to
1445 North Highway
Colville, WA 99114
2100 MILLENNIUM WOOD STOVE
Advanced Combustion Technology (ACT)
IMPORTANT SAFETY NOTES:
prevent staining from fingerprint oils. See page 20 for details.
SAVE THESE INSTRUCTIONS
Part 250-6931C
November 3 2004
R
Tested and
Beaverton
O-T L
Oregon USA
Listed by
C
OMNI-Test Laboratories, Inc.
www.quadrafire.com

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 2100 Millennium

  • Page 1 2100 MILLENNIUM WOOD STOVE Advanced Combustion Technology (ACT) Tested and Beaverton O-T L Oregon USA Listed by OMNI-Test Laboratories, Inc. This manual contains instructions for Installation, Operation & Maintenance. Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death.
  • Page 2 finishing options and accessories to complement your home’s décor, individualize the use of your appliance, and provide financial options in acquiring a quality hearth appliance. Ask your Quadra-Fire Dealer for information on these options. From design, to fabrication, to shipping: Our guarantee of quality is more than a word, it’s Quadra-Fire tradition, and we proudly back this tradition with a Limited Lifetime Warranty.
  • Page 3: Table Of Contents

    2100 ACT Millennium Wood Stove TABLE OF CONTENTS QUADRA-FIRE 2100 MODEL NAME Listings & Safety Cautions ........4 MILLENNIUM WOOD STOVE Installation Materials Needed ......4 Venting System Overview ........4 Dimensions ............5 Serial Number Vent Specifications ..........5 Serial Number Label Location ......
  • Page 4: Listings & Safety Cautions

    OMNI-Test Laboratories, Inc. to UL Safety Standard heating appliance and close to the sleeping areas. Follow 1482, and ULC S627, and (UM) 84-HUD. The 2100 Millennium the smoke detector manufacturer’s placement and installation is approved for mobile home installations when not installed instructions, and be sure to maintain regularly.
  • Page 5: Dimensions

    2100 ACT Millennium Wood Stove DIMENSIONS SIDE VIEW FRONT VIEW 21-3/8" (543mm) 25-7/8" (657mm) 7-7/16" 10-11/16" (189mm) 23-1/16" (332mm) (271mm) 5-3/8" (137mm) 12-3/4" (324mm) 13-5/8" (346mm) Back of the stove to glass 9-3/8" 17.0" (432mm) (238mm) 22.0" (559mm) 26-1/2" (673mm) 15-3/4"...
  • Page 6: Clearances To Combustibles

    2100 ACT Millennium Wood Stove CLEARANCES TO COMBUSTIBLES (UL AND ULC) BACKWALL / SIDEWALL ALCOVE SIDE VIEW 90° OFF TOP UP & OUT CEILING CLEARANCE STOVE TO CEILING CLEARANCE CORNER INSTALLATION ALCOVE TOP VIEW MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters) NOTE: All "A"...
  • Page 7: Floor Protection

    2100 ACT Millennium Wood Stove FLOOR PROTECTION FLOOR PROTECTION: Floor protector must be noncombustible material, extending beneath heater and to the front/sides/rear as indicated. The floor must be non-combustible or otherwise adequately protected from radiant heat given off by the unit and from sparks and falling embers. A layer of thin brick or ceramic tile over a combustible floor is not sufficient.
  • Page 8: Chimney Height / Draft & 2-10-3 Rule

    CHIMNEY HEIGHT/DRAFT To be sure that your Quadra-Fire stove burns properly, the chimney draft (static pressure) should be approximately -.10” water column (W.C.) during a high burn and -.04” W.C. during a low burn, measured 6” (152mm) above the top of the stove after one hour of operation at each burn setting.
  • Page 9: Flue Systems & Chimney Connections

    2100 ACT Millennium Wood Stove MASONRY CHIMNEY (Cont’d) FLUE SYSTEMS There are two separate and different parts to a flue system: the The flue should be checked to determine that it is not too chimney connector and the chimney itself. large for the stove.
  • Page 10: Solid Pack With Metal Supports

    2100 ACT Millennium Wood Stove SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE For the method of installation to a masonry chimney shown in Figures 12A & 12B on page 12, it will be necessary to purchase a 12” (305mm) long 8" (203mm) inside diameter, section of prefabricated listed solid pack chimney to use as a thimble.
  • Page 11 2100 ACT Millennium Wood Stove SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE (Cont’d) First, make the frame for the thimble, ensuring it is no smaller than 14" (368mm) square, to maintain a 2" Min. Chimney Clearance (51mm) air space around the chimney section. Min.
  • Page 12: Metal Pre-Fab Chimney

    2100 ACT Millennium Wood Stove CONNECTION TO A METAL PRE-FABRICATED CHIMNEY When a metal prefabricated chimney is used, Listed Chimney the manufacturer’s installation instructions Attic Listed Cap Insulation must be followed precisely. You must also Combustible Shield Maintain 2" (51mm) Storm Collar Ceiling purchase (from the same manufacturer) and...
  • Page 13: Mobile Home

    2100 ACT Millennium Wood Stove MOBILE HOME INSTALLATION You must use a Quadra-Fire Outside Air Kit Part 831-1780 for installation in a mobile home. An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow. It must be...
  • Page 14: Accesssory / Parts Replacement Outside Air Kit

    Included in Kit: 1 front cover; fiberglass rope; 2 vent straps; venting flange & 4 screws; termination cap & screws. Discard the 2 side covers and 1 rear cover as they are not needed for your Quadra-Fire 2100 Millennium. Items Needed for Installation: 4” flex pipe in the length as required for your installation; Phillips screwdriver; Silicone sealant;...
  • Page 15: Operating Instructions

    In order burned and only charcoal remains. This is a naturally to improve the situation, we at Quadra-Fire have developed clean portion of the burn. The coals burn with hot blue flames.
  • Page 16: Operating Instructions

    IMPORTANT - PLEASE READ BEFORE USING STOVE For maximum operating efficiency with the lowest emissions, follow these operating procedures: Regardless of desired heat output, when loading stove, burn your Quadra-Fire with both air controls wide open for 5 to 15 minutes.
  • Page 17: Opacity

    19) If your Quadra-Fire wood stove is equipped with an optional blower, you should follow these guidelines: Initial (cold) start-up: Leave blower off until your stove is hot and a good coalbed is established. The blower may be turned on approximately 15 minutes after loading the stove with fuel.
  • Page 18: Maintenance: Creosote Removal

    FIREBRICK FORMATION AND NEED FOR REMOVAL: When wood is The firebox of your Quadra-Fire stove is lined with high quality burned slowly, it produces tar and other organic vapors firebrick, which has exceptional insulating properties. There is no which combine with expelled moisture to form creosote.
  • Page 19: Brick Replacement

    2100 ACT Millennium Wood Stove BRICK REPLACEMENT INSTRUCTIONS Brick Set Part 831-1890 1. After the coals have completedly cooled, remove all old brick and ash from unit and vacuum firebox. Remove new brick set from box and lay out to diagram shown. Lay bottom bricks in unit.
  • Page 20: Door Handle Assembly

    BAFFLE REMOVAL AND INSTALLATION NOTE: The baffle in the 2100 Millennium is 2700° Fiber Board. Removing hardware exposed to combustion processes can be frustrating. If your reason for removing the baffle is simply to clean the chimney, you have alternatives which will save time and effort.
  • Page 21: Exploded View

    2100 ACT Millennium Wood Stove EXPLODED VIEWS Nbr Part Name Door, Cast Door Handle Glass, Replacement Glass Frame Assembly Glass Frame Screws (10) Hinge Pins Latch, Cam Latch Cam key Locking Nut 10 Spring Handle, 1/2” 11 Trim for Door (Trim Door Assembly only) 12 Washer, Spacing DOOR, GLASS AND DOOR HANDLE ASSEMBLY...
  • Page 22: Accessory & Replacement Parts List

    832-0630 ..Spring Handle, Air Control, ¼”, Gold, (pair) APPLIANCE 2100 Millennium Advanced Combustible Technology (ACT) 21M-GT 2100 Millennium, Gold Trim Door, Pedestal 21M-NT 2100 Millennium, Nickel Trim Door, Pedestal Page 22 250-6931C November 3, 2004...
  • Page 23: Warranty Policy

    2100 ACT Millennium Wood Stove Lifetime Warranty LIMITED LIFETIME WARRANTY The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home Technologies will repair or replace them. These items include but are not limited to steel and cast iron components, all gas burners, gas logs, combustion chambers, heat exchanger systems, stainless steel firebox components, plating, doors, glass damaged by thermal breakage, steel baffle supports, steel and ceramic baffles and manifold tubes.
  • Page 24 Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES www.quadrafire.com Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, call 1-800-926-4356 CAUTION • Do NOT discard this manual.