7000 and 9000 Electronic Operation
Jets 2: (Optional on 7000) Press the "Jets 2" button once to
turn pump 2 on or off, and to shift between low and high
speeds if it is a two-speed pump. If left running, the pump
will turn off after 15 minutes.
Option (optional Blower or Mister) Press the "Option"
button to turn the optional equipment on and off. If left
on, the equipment will automatically turn off after 15 min-
utes.
Light Some systems are equipped with both a spa light
and a fiber optic light. Depending upon how your spa is
equipped and configured, the "Light" button will operate
in one of three ways:
Press the "Light" button to turn the spa light on and off,
and to shift between dim and bright settings if your light
is dimmable. On dim, the LCD will show center circle
plus one quarter of the light beams. Half of the light
beams will show on medium brightness, and all of the
light beams will show on bright.
2) (9000 Only) If a fiber-optic light with wheel is
installed, press the "Light" button once to start the light
and wheel, press it again to stop the wheel, and then again
to turn the light off. The fiber icon stands still when the
fiber optic light is on by itself, and rotates when the color
wheel is also on. Depending on how your system is
configured, the spa light or an additional light may come
on with the fiber-optic light when pressing this button.
3) (7000 Only) If a fiber-optic light without a separate wheel
stop is installed, press the "Light" button to turn it on and off.
If any light is left on, it will automatically turn off after 4
hours.
Invert Press the "Invert" button to change the numbers in
the display to read upside down. Another press returns
display to the right-side-up position.
Locking the Panel Press "Time" "Jets 1" then "Warm"
within 3 seconds. When locked, the panel will display
"PANEL LOCK". All buttons are frozen except the
"Time" button. To unlock the panel, press "Time" "Jets
1" then "Cool."
Locking the Set Temperature Press "Warm" or "Cool"
then "Time," "Jets 1," and "Warm" within 3 seconds to
activate the lock. The panel will display "TEMP
LOCK" when the set temperature is locked. To unlock
the set temperature, press "Warm" or "Cool" then
"Time," "Jets 1" and "Cool."
Page 34
Circ Pump (optional) If your system is equipped with a circ
pump, it may be configured to work in one of two different
ways:
1) The circ pump operates continuously (24 hours) with the
exception of turning off for 30 minutes at a time when the water
temperature reaches 3°F above the set temperature (most likely
to happen in very hot climates).
2) The circ pump will come on when the system is checking
temperature (polling), during filter cycles,during freeze
conditions, or when another pump is on.
Preset Filter Cycles There are two filter cycles per day. The
start/end times of each cycle are programmable. To program, set
time as instructed above, then press "Mode/Prog" to advance to the
next setting (or to exit after the last setting). The default filter cycles
are as follows: The first filter cycle is automatically activated at
8:00 AM and operates the pump until 10:00 AM. The filter 1
indicator icon will light when filter 1 is running.
The second filter cycle is automatically activated at 8:00 PM
and operates the pump until 10:00 PM. The filter 2 indicator
icon will light when filter 2 is running. The pump and the ozone
generator will run during filtration. At the start of each filter
cycle, the blower will run on highest speed for 30 seconds to
clean out the air channels. The lowest speed of pump 2 and
pump 3 will run for 5 minutes. Time of day is not preserved on
7000 systems; however, filter cycles are.
power loss or shut down, the time of day will need to be reset
for filter cycles to run according to your desired programming.
Clean-up Cycle When the pump or blower is turned on by a
button press, a clean-up cycle begins 30 minutes after the pump
or blower is turned off or times out. The pump and the ozone
generator** will run for one hour.
Ozone (optional) On most systems, the ozone generator (if
installed) runs during filter cycles (except when pump 1 is
operating at high speed on a non-circ system) and
during clean-up cycles. On some systems, the ozone
generator operates whenever the pump runs. If your
system is configured with the optional ozone disable
feature, the ozone generator will turn off for 1 hour any time a
function button (Jets 1, Jets 2, Option, etc.) is pressed.
Freeze Protection If the temperature sensors detect a drop to
44°F within the heater, then the pump automatically activates
to provide freeze protection. The equipment stays on until 4
minutes after the sensors detect that the spa temperature has
risen to 45°F or higher. In colder climates, an optional
additional freeze sensor may be added to protect against freeze
conditions that may not be sensed by the standard sensors.
Aux freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch and without
a 4-minute delay in turnoff.
Owner's Manual
In the event of
Revised 01/01/04