7000 AND 9000 ELECTRONIC OPERATION
These instructions will describe features and options that your particular spa may not be equipped with.
Initial Start-up:
When your spa is first powered up, it will display some configuration codes and then go into Priming Mode
(Pr will appear on the display panel) This mode will last up to 4 minutes and then the spa will began to heat to its
pre -programmed temperature of 100°F. You can exit the Priming mode early by pressing Up or Down arrow.
Temp Set: (80°F - 104.°F / 26.0°C - 40.0°C) The
start-up temperature is set at 100°F/37.5°C. The last
measured temperature is constantly displayed on the
LCD. Note that the last measured spa temperature displayed is
current only when the pump has been running for at least 2
minutes.
Warm / Cool Press the "Warm" or "Cool" (Up or
Down) button once to display the set temperature. Each
time either button is pressed again, the set
temperature will increase or decrease depending on which
button is pressed. After three seconds, the LCD will auto-
matically display the last measured spa temperature.
Time
When time hasn't been programmed, the TIME icon
flashes. To set the time, press "Time" then "Mode/Prog."
Use the "Warm" and "Cool" buttons to adjust time. See
the next page for more detailed instructions.
Mode/Prog
This button is used to switch between standard,
economy, and sleep modes. Press "Mode/Prog" to enter
mode programming, press "Cool" to cycle through to
desired mode (LCD flashes until confirmed), then press
"Mode/Prog" to confirm selection.
Standard mode: is programmed to maintain the desired
temperature. Note that the last measured spa temperature
displayed is current only when the pump has been run-
ning for at least 2 minutes. The "STAND" icon will dis-
play until the mode is changed.
Revised 01/01/04
Economy mode heats the spa to set temperature only during filter
cycles. The "ECON" icon will display until mode is changed.
Pressing "Jets 1" while in Economy mode puts the spa in Standard-
in-Economy mode, which operates the same as Standard Mode, then
reverts to Economy Mode automatically after 1 hour. During this
time, a press of the "Mode/Prog" button will revert to Economy
Mode immediately.
Sleep mode heats the spa to within 20°F of the set temperature
only during filter cycles. The "SLEEP" icon will display until
mode is changed.
Standby mode:
Pressing "Warm" or "Cool" then "Jets 2" will turn off all spa func-
tions temporarily. This is helpful when changing a filter. Pressing
.
any button resets the spa
Jets 1:
Press the "Jets 1" button once to turn pump 1 on or off, and to
shift between low and high speeds if equipped. If left running,
the low speed turns off after 2 hours and the high speed turns
off after 15 minutes. On non-circ systems, the low speed of
pump 1 runs when the blower or any other pump is on. It may
also activate for at least 2 minutes every 30 minutes to detect
the spa temperature (polling) and then to heat to the set
temperature if needed, depending upon mode. When the low
speed turns on automatically, it cannot be deactivated from the
panel; however, the high speed may be started.