ELECTRICAL RATING FOR 1100 SERIES SPAS
120 Volts
15 Amps
60 Hertz
2 Wires plus Ground
Min. Supply conductor 20 Amp
Circuit Breaker 20 Amps
For units bearing the UL mark the power supply cord is provided with integral GFCI.
For units bearing the C-UL mark, the power supply cord is not provided. Field wiring leads are provided inside
the conduit body with a minimum of 6-inches in length.
240 Volt
40 Amps (Must use a 40Amp GFCI Circuit Breaker)
60 HTZ
4 Wire Min. 8 AWG Copper
Revised 01/01/04
Self-Diagnostics
Display Messages for the 1100 Series Spas
Meaning
"Overheat" The spa has
shut down. Either the spa has
reached a temperature of
112˚F or the High-limit
sensor
has
overheating in the heater
manifold.
"FL" A pressure switch has
detected a loss of water flow.
"Sensor" Spa has shut down.
The
Hi-limit/Temperature
sensor has malfunctioned.
120/240 Volt Convertible
Action Required
DO NOT ENTER THE SPA WATER.
Remove the spa cover and let the water
cool.
automatically reset. If the spa does not
automatically reset, press any pad on the
detected
topside control panel. If the spa still won't
reset, turn off the power and call your
local authorized service center.
Check the filter for debris. If it's dirty,
clean it. (See page 14 for cleaning
instructions) If the problem persist, call
your local authorized service center.
Call your local authorized
service center.
Self Diagnostics
At
110˚F,
the
spa
should
Page 25