Power Requirements - Jacuzzi J - 315 Owner's Manual

J-300 collection
Hide thumbs Also See for J - 315:
Table of Contents

Advertisement

J-300
120/240 Volt Convertible Models
A spa connected to a 120 VAC electrical service must be located close
enough to a grounded, grounding-type electrical outlet so that the
included 10 feet (3m) power cord can be plugged directly into it. DO NOT
USE AN EXTENSION CORD as this could cause damage to the spa's
equipment due to insufficient voltage. The power supplied to this spa
must be a dedicated circuit with no other appliances or lights sharing the
power provided by the circuit.
6.0

Power Requirements

Jacuzzi spas are designed to provide optimum
performance and flexibility of use when connected to the
maximum electrical service listed below. Minor circuit
board modifications can be performed to allow your new
spa to accept an electrical service other than the factory
operation setting.
Note: Refer to pages 48-52 for circuit board configuration details or
contact your authorized Jacuzzi dealer.
North American J-335, J-345, J-355, J-365 and J-375 Models (60 Hz)
Circuit Breaker (2-Pole):
Number of Wires:
Frequency:
Current Draw:
In 40A configuration, the heater will not operate while either jets
*
pump is running in high speed. Note: pump 2 runs only in high
speed.
** In 50A configuration, the heater will not operate while both jets
pumps are running in high speed. This is the factory setting.
Note: pump 2 runs only in high speed.
*** In 60A configuration the heater will operate while both jets pumps
are running in high speed.
12
240V/40A*
240V/50A**
40A
3
60 Hz
26A
240V/60A***
50A
3
60 Hz
60 Hz
36A
60A
3
45A