Scc Test Display With Error - DEC 600s Owner's Manual

Printer owner's guide
Hide thumbs Also See for 600s:
Table of Contents

Advertisement

Example
If a diagnostic test fails, a display similar to the one shown
Diagnostic Test
in Figure 14–2 appears, containing information important to
with Error
helping you determine the source of the problem.
Figure 14–2 SCC Test Display with Error
>>> test scc
? T-ERR-SCC-MOUSE - 0 char rcvd
?? 004
>>>
Understanding
In the previous example, the SCC test failed during testing of
the test
the mouse line. This means that the mouse is not being seen
Command
by the system. Check the mouse connector to make sure that it
Display
is properly connected to the mouse/keyboard connector. If it is
properly seated, you may have a defective mouse. Contact your
Digital service representative.
Use the following syntax to run a test on a TURBOchannel
TURBOchannel
Test Syntax
option connected to a specific slot number.
>>> test device_name
where device_name is the TURBOchannel device name followed
by the slot number of the device you wish to test.
Use the following syntax to execute a selected test in a
TURBOchannel option:
>>> test device_name test_name
where device_name is the TURBOchannel device name and
test_name is one of the test names listed in TURBOchannel Test
Commands.
SCC 0x0060
84 FAIL
Return
Running Diagnostic Tests
Return
Running Diagnostic Tests 14–7