Installation and
Operation
This section describes the installation and the operation of the DTP DVI 301 Tx/Rx Extender,
including:
•
•
•
Mounting the Transmitter or Receiver
CAUTION: Installation and service must be performed by authorized personnel only.
Mounting instructions and the applicable optional hardware can be found in the
"Reference
transmitter or receiver can be placed on a tabletop, mounted on a rack shelf, or mounted
under a desk or tabletop. The receiver can also be mounted on a projector bracket.
Connections
Transmitter Connections
DDC ROUTE
POWER
OUT
REMOTE
12V
0.7 A MAX
ON
1 2
ANALOG AUDIO
SPARE
LOCAL
Rear
.
6
Figure 2.
a
b
Mounting the Transmitter or Receiver
Connections
Operation
Information" section. The 1-inch high, quarter rack width DTP DVI 301
SIG
LINK
RS-232
IR
DTP OUT
Tx
Rx
Tx
Rx
5
4
DTP DVI 301 Tx Connectors
DVI-D connector — Connect a DVI cable between this port and the DVI output
port of the digital video source. See
assignments.
Local Output connector — If desired, connect a DVI monitor for local monitoring of
the input digital image. See
NOTES: • The local output is limited to a data rate of 4.95 Gbps (1.65 Gbps per
color).
• In a system where the local output is not used, ensure that you power up
the end display first before the video source. Route the DDC to the remote
end (see the DDC Route DIP switch [see
section]).
INPUTS
DVI-D
Front
1
"DVI connector pin
"DVI connector pin
assignments" for pin assignments.
item
DTP DVI 301 • Installation and Operation
LOCAL OUTPUT
AUDIO
DTP DVI 301 Tx
3
2
assignments" for pin
c
, in the "Operation"
3