Weil-McLain GV90+ Installation And Start-Up Manual page 5

Series 2 gas-fired water boilers
Hide thumbs Also See for GV90+:
Table of Contents

Advertisement

GV90+
Series 2
OAS·FtRED WATER BOILER -
Boiler Manual
Please read before proceeding
Hazard definitions
The
following
defined
terms
are
used throughout this
manual
to
bring
attention
to
r.he prestnce of
hazards of
various
risk lt•ttls
or
to
important info rmation
concerning the life
of the
product.
lndicares prt.Sence
of hazards thar
wlll
cause
sevt-rt
perSonal
injur-J'•
dearh
or substant ial property
damage.
lndicares prt.Sence of hazards that
can cause
sevt-rt
perSonal
injur)'•
dearh
or substant ial property
damage.
!A
CAUTION
1
lndicares presence of hazards that will or can
cause
m
inor
ptmnal
injury
or
p
roptrty
damage.
NOTICE
IAwARNIN&
l
NOnCE
Jndicares
spedal
insrruct
ions on insrallation.
Opt-r
ation o
r
maintenance thar a
re
importanr
bur
not
related
to ptrsonal
injury
or
proptrty damage.
Ins
taller-
Read
all instructions.
induding
this
manual and
all other
information shipped
with
the
boiler> before
installing. Perfonn steps
in
the
order
gi
..
·tn.
U
ller
-
This
manual
is for
use only
by
a qualified
he-ating
installer/service
technician.
Refer
to
User's
Jn:f'onnation ManuaJ for
your
reference.
User
-
Ha\'t this
boiler
serviced/inspected
by
a
qualified service
technidan,
at
least
annually.
faj
lure to
comply
with
the above
could result in
sevtrt
personal
injury, death
or substantia]
proptrty
da.mage.
W~itt
in the
CP
numbtr in the
space
provided
on
the
Installation
certificate on
page
90
if not
already
shown.
\Vhen
calling
or
writing about the boiler- Please
have the boiler
model nwnber
from the boiJtr
raring
label and the
CP
number
from
the
boiler
jacket.
Consider piping and
installation
when
determining
boiler
location.
Any claims
for
damage
or
shorrage
in
shipment
must be
filed
immedlatelyagainst the transportation
company
by
the
consignee.
Commonwealth of Massachusetts
When
the boil-er
is
installed
within
the
Commonwealth of
M..,.chu.setts,
comply with
< he following.
This
product must be
installed by a licensed
plumber
or
gas
fitter.
If
antifreeze
is used,
a reduced pressure back-flow preventer
d.,;ce
shall
be
uStd.
tf
sidewaJI
\.'tnt
or
venr/air
is insralled>
see
instructions
on
page
34.
Part
number 550-1+2-783/1012
~WARIMI
Failure
to adhere ro
the guidelines
on
thi.s
page can
resull
in
severe
personal
injury,
Cleath
or
substantia]
proptrty
damage.
When
..,,.,.;cing boiler
-
To avoid electric
shock, disconnecr
electricaJ
supply
before
performing maintenance.
To avoid
severe
burns, allow
boiler
ro
cool
before
performing maintenance.
This boiler
contains ceramic
t'ibtr
and
fiber~lass
materials.
Refer
to
the WARNING and
instructions
on
page 106.
Boiler operation
-
Do
not
bloc.
k
flow
of combustion or \<entilation
air
to
boiler.
Should
""erhNUng occur or g
..
aupply
11111
to
tMit
off,
DO NOT
tum off
or
disconnect electrical
sup.
P .Iy
t~
circulator. Instead>
sh~r
off
the gas supply
at
a
l
ocanon
externaJ
to
the
apphanct.
Do
not
UM
thla
boiler
H any
~h
.. _.,under
woter.
Immediately call a qil3lified service
techni-
cian
to
inspect tht
boiler
and
to
rtpl.act any
va:rt
of
the
control
system and
any
gas
control
that
has
bft.n
under
water.
Combustion
air-
DO
NOT
Install combulllon air Intake
whwe
there
It
a
rltk
of combustion air
contamln.Uon.
Carbon monoxide detector
-
For
OII'Cid
Exhaust
units, a
carbon
monoxide
detec-
tor
is
required in
the boiler
room.
The
carbon mon-
oxide dttecror
must
be
wired
on
the
same
electrical
circuit
as
the boiler.
For Direct
V•nt
units, a carbon
monoxide
dttecror
that
i.s
wirtd
on
the
same
electrical
d
rcuir
as
the boiler
is
strongly
recommended.
Boiler
water-
Thoroughly flush the system (without boiler con-
neoted)
to
removeS<'dinlenl
TbehbUI-ellic.iency
heat
exd1anger
can
be damaged
by build-up
or corrosion
due to
sedimtnr.
Do not
lL~t
JH:troleum-based deaning
or staling
compounds in
boiler
S)'Stem. Gaskets
and
seals
in
the
system
may bedamage<t.
This
can
result
in substantial
property damage.
LNko
ln boiler
0<
piping ,.....t
be
repeiN<I ot once
to
P<8Yenl
moke-t~p
woter.
Use thlo
boiler ONLY
In • ciOMd-toop system.
Continual
fre.sh make-up
wat-er
will
rtduct
boiler life. MineraJ buildup in heat
exchangers reduces
heat
transfer,
overheats the
mate-
rials,
an
<I
cause.s tanure.
Addition
of
oxygen
carried
in
by
make-up
water
can
cause internal
corrosion.
Do
not
add cold w.ter
to
hot
bolter.
ThennaJ
shock
can
cause
heat exchanger
to
crack..
Freeze
protection
fluid• -
NEVER u.se
automoti\·t
or
standard
glycol
antifrtt:ze.
Use only
freeu-protectlon
fluids
made for hydronic
systems. Follow
aU
guidelines
gi,·tn br. the
antifreeze
manufucturer. Thoroughly
dean ana
flush
apy
re-
placement boiler
system
that has used
gl)'cOI
before
msr.alling
the
new boiler.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qv90+3Ov90+4Qv90+5Ov90+6

Table of Contents