At this point you are ready to perform the initial power-up sequence and optical
alignment procedure, which is summarized in Table 3-6 and described in detail in the
sections that follow.
This procedure assumes the following:
• You are installing a projector equipped with anamorphic lenses. (If not, you can skip
those tasks relating to the anamorphic lenses.)
• You have already completed the physical installation of the projector and Dimension
Digital Controller as described in the previous sections. If you have not, do so now.
• You have connected the various system components to each other, to external
equipment and to AC power. If you have not, do so now.
Table 3-6. D-73d Optical Alignment Procedure (with Anamorphic Lenses)
START
Dimension Digital Controller
1.
Leave system off for now.
2.
Connect an active 1080p source to the
HDMI 1 connector.
Dimension Digital Controller
1.
Turn on system and select the HDMI 1
input.
2.
Select Calibration -> Adjustment Mode
and set it to Primary.
3.
Select Service -> Test Video and choose
Primary Alignment.
D-73d Series Installation/Operation Manual
Projector
1.
Mount the projector (refer to
Mounting the D-73d on page 36).
2.
Mount the Dimension Digital
Controller (refer to Mounting the
Dimension Digital Controller on
page 37).
3.
Connect system components to
each other and to external
equipment (refer to System
Interconnections on page 38).
4.
D-73d/CineWide with AutoScope
only: Install anamorphic lenses in
retracted position (out of the light
path) and ensure that the AutoScope
transport motor AC switch is in the
"off" position.
5.
Loosen the lock screw for both
primary lenses.
Projector (Align Primary/Left Image
with Screen)
1.
Adjust the ceiling mount to correct
for image keystone and clocking.
2.
Align the image to the screen by
adjusting the Left (top) primary lens
zoom, focus and H/V offset.
3.
Tighten the Left primary lens lock
screw.
51
3.8
Power-Up Sequence
and Optical
Alignment Procedure
Note: At this point the anamorphic
lenses are simply used as weight to
maintain the correct center of gravity
while you adjust the primary lens, so
that the projector won't shift when you
add the anamorphic lenses later.
Notes:
1.
You must enter a passcode to
access the Calibration or Service
menu.
2.
The lock screw locks all lens
adjustments except for focus.
Installation