• Adjusting the Yaw: Loosen the Yaw/X-Adjustment Levers to allow the lens to pivot
freely from side to side. Then, angle the lens to even out any left-right pincushion
distortion:
Wrong Position
Once the proper lens angle has been set, firmly tighten the Yaw/X-Adjustment
Levers to secure the lens in place.
Adjusting the Right (Bottom) Anamorphic Lens:
1. On the Dimension Digital Controller remote control or front panel, press MENU.
2. Select Calibration from the Main Menu.
3. Select Adjustment Mode from the Calibration Menu and set it to Secondary.
4. Press EXIT (or MENU) repeatedly to return to the Main Menu.
5. Select Service from the Main Menu.
6. Select Test Video from the Service Menu and choose Secondary Alignment.
7. Align the secondary (right-eye) image to the screen by adjusting the Right (bottom)
anamorphic lens to produce the least amount of distortion. (Refer to the previous
section, Adjusting the Left (Top) Anamorphic Lens.)
D-73d Series Installation/Operation Manual
Anamorphic Lens (Top View)
Correct Position
61