Platform Management Functional Overview
2.
For fan speed control in 3rd party chassis
3.
Temperature margin from throttling threshold
4.
Absolute temperature
5.
PECI value or margin value
6.
On-die sensor
7.
On-board sensor
8.
Virtual sensor
9.
Available only when PSU has PMBus*
The following illustration provides a simple model showing the fan speed control structure that
implements the resulting fan speeds.
6.10.3
Fan Profiles
The server system supports multiple fan control profiles to support acoustic targets and
American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE)
compliance. The BIOS Setup utility can be used to choose between meeting the target acoustic
level or enhanced system performance. This is accomplished through fan profiles.
The BMC supports eight fan profiles, numbered from 0 to 7.
Type
OLTT
OLTT
OLTT
OLTT
OLTT
OLTT
OLTT
50
Figure 15. Fan Speed Control Process
Table 18. Fan Profiles
Profile
0
Acoustic, 300M altitude
1
Performance, 300M altitude
2
Acoustic, 900M altitude
3
Performance, 900M altitude
4
Acoustic, 1500M altitude
5
Performance, 1500M altitude
6
Acoustic, 3000M altitude
Intel® Server Board S1200V3RP TPS
Details
Revision 1.2