Intel SE7230NH1-E User Manual
Hide thumbs Also See for SE7230NH1-E:
Table of Contents
  • Manual Organization
  • Product Accessories
  • Additional Information and Software
  • Important Safety Instructions
  • Consignes de Sécurité
  • Instrucciones de Seguridad Importantes
  • Warnings
  • Table of Contents
  • Server Board Features

    • Figure 1. Intel ® Server Board SE7230NH1-E
    • Table 1. Server Board Features
    • Connector and Header Locations
    • Figure 2. Server Board Connector and Component Locations
    • Configuration Jumpers
    • Table 2. Configuration Jumpers
    • Back Panel Connectors
    • Table 3. LED Information
    • Hardware Requirements
      • Processor
      • Memory
      • Power Supply
    • Optional Hardware
      • Hard Disk Drives
  • Server Utilities

    • Using the BIOS Setup Utility
      • Starting Setup
      • If You Cannot Access Setup
      • Setup Menus
      • Table 4. Keyboard Commands
    • Upgrading the BIOS
      • Preparing for the Upgrade
      • Upgrading the BIOS
    • Clearing the CMOS
  • Hardware Installations and Upgrades

    • Before You Begin
      • Tools and Supplies Needed
    • Installing and Removing Memory
      • Figure 3. DDR Vs. DDR2 Dimms
      • Figure 4. Installing Dimms
      • Installing Dimms
      • Removing Dimms
    • Installing or Replacing the Processor
      • Installing the Processor
      • Figure 5. Lift Processor Socket Lever
      • Figure 6. Lift Processor Load Plate
      • Figure 7. Removing Protective Processor Cover
      • Figure 8. Installing the Processor
      • Figure 9. Removing the Socket Protective Cover
      • Installing the Active Heat Sink
      • Figure 10. Closing the Load Plate and Socket Lever
      • Installing the Passive Heat Sink
      • Figure 11. Installing the Active Heat Sink
      • Removing a Processor
      • Figure 12. Installing the Passive Heat Sink
    • Replacing the Backup Battery
    • Figure 13. Removing the Battery
  • Troubleshooting

    • Resetting the System
    • Problems Following Initial System Installation
    • Hardware Diagnostic Testing
      • Verifying Proper Operation of Key System Lights
      • Confirming Loading of the Operating System
    • Specific Problems and Corrective Actions
      • Power Light Does Not Light
      • No Characters Appear on Screen
      • Characters Are Distorted or Incorrect
      • System Cooling Fans Do Not Rotate Properly
      • Diskette Drive Activity Light Does Not Light
      • CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light
      • Cannot Connect to a Server
      • Problems with Network
        • Problems with Newly Installed Application Software
        • Problems with Application Software that Ran Correctly Earlier
      • Devices Are Not Recognized under Device Manager
      • LED Information
      • Table 5. LED Information
      • BIOS POST Beep Codes
      • Table 6. POST Error Beep Codes
  • A Getting Help

    • World Wide Web
    • Telephone
  • B Safety Information

    • English
      • Server Safety Information
      • Safety Warnings and Cautions
      • Intended Application Uses
      • Site Selection
      • Equipment Handling Practices
      • Power and Electrical Warnings
      • System Access Warnings
      • Rack Mount Warnings
      • Electrostatic Discharge (ESD)
      • Other Hazards
      • Sicherheitshinweise für den Server
      • Sicherheitshinweise und Vorsichtsmaßnahmen
      • Zielbenutzer der Anwendung
      • Standortauswahl
      • Handhabung von Geräten
      • Warnhinweise für den Systemzugang
      • Elektrostatische Entladungen (ESD)
      • Andere Gefahren
    • Français
      • Consignes de Sécurité Sur Le Serveur
      • Sécurité: Avertissements Et Mises en Garde
      • Domaines D'utilisation Prévus
      • Sélection D'un Emplacement
      • Pratiques de Manipulation de L'équipement
      • Décharges Électrostatiques†(ESD)
      • Autres Risques
      • Información de Seguridad del Servidor
      • Advertencias y Precauciones sobre Seguridad
      • Aplicaciones y Usos Previstos
      • Selección de la Ubicación
      • Manipulación del Equipo
      • Advertencias el Acceso al Sistema
      • Descarga Electrostática (ESD)

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 81

Quick Links

®
Intel
Server Board SE7230NH1-E and
®
Intel
Server Platform SR1475NH1-E
User's Guide
Intel Order Number D23185-004

Advertisement

Table of Contents
loading

Summary of Contents for Intel SE7230NH1-E

  • Page 1 ® Intel Server Board SE7230NH1-E and ® Intel Server Platform SR1475NH1-E User’s Guide Intel Order Number D23185-004...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Manual Organization

    Intel Server Board SE7230NH1-E User Guide. For the latest version of this manual, refer to http://support.intel.com/support/motherboards/server/SE7230NH1-E/.
  • Page 4: Product Accessories

    Processor, memory DIMMs, hard drive, floppy drive, CD-ROM or DVD-ROM drive, RAID controller, operating system. For information about which accessories, memory, processors, and third-party hardware have been tested and can be used with your board, and for ordering information for Intel products, see http://support.intel.com/support/motherboards/server/SE7230NH1-E/ compat.htm.
  • Page 5 For software to manage your Intel® server Intel Server Management Software For drivers Driver (for an extensive list of drivers available) Operating System Driver (for operating system drivers) For firmware and BIOS updates, or BIOS Firmware Updates recovery For diagnostics test software Diagnostics See also the Intel®...
  • Page 6 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 7: Important Safety Instructions

    Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm.
  • Page 8: Warnings

    Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® ® viii Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 9: Table Of Contents

    Removing DIMMs ........................15 Installing or Replacing the Processor ..................15 Installing the Processor ......................15 Installing the Active Heat Sink ....................18 Installing the Passive Heat Sink ....................19 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 10 Zielbenutzer der Anwendung ....................43 Standortauswahl ........................43 Handhabung von Geräten ......................43 Warnhinweise für den Systemzugang ..................45 Elektrostatische Entladungen (ESD) ..................46 Andere Gefahren ........................47 Français ..........................48 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 11 Europe (CE Declaration of Conformity) ..................68 Taiwan Declaration of Conformity (BSMI) ................68 Korean Compliance (RRL) ......................69 ® D Intel Server Issue Report Form ................ 71 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 12 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 13 Figure 10. Closing the Load Plate and Socket Lever ............... 18 Figure 11. Installing the Active Heat Sink................. 19 Figure 12. Installing the Passive Heat Sink................20 Figure 13. Removing the Battery....................22 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide xiii...
  • Page 14 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 15 Table 3. LED Information ......................6 Table 4. Keyboard Commands....................10 Table 5. LED Information ......................31 Table 6. POST Error Beep Codes.................... 32 Table 7. Product Certification Markings ................... 66 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 16 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 17: Server Board Features

    Intrusion Main Power Socket Serial ATA Front Panel SCSI LED Serial ATA Floppy Sys Fans Sys Fan 4 Sys Fan 3 TP01795 ® Figure 1. Intel Server Board SE7230NH1-E Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 18: Table 1. Server Board Features

    Integrated stand-alone ATI ES1000 graphics engine that supports standard SVGA drivers with analog display capabilities. The graphics subsystem has 16 MB of dedicated memory to support the onboard video controller Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 19 Four 8-pin dual rotor fan headers for Intel High Density applications (Intel Server Chassis SR1475 and Intel Server Platform SR1475NH1-E) Other Intel Light Guided Diagnostic LED’s to display POST code indicators during boot (LX version only) Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 20: Connector And Header Locations

    L. Serial A and Video Port Y. SysFan5 - LX version only LL.CMOS Config Jumper M. PS2 Stacked Mouse/Keyboard Z. SysFan4 MM.HSBP Connector Figure 2. Server Board Connector and Component Locations Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 21: Configuration Jumpers

    Pins 1-2 should be jumpered for normal system operation. If pins 2-3 are jumpered, the CMOS settings will be cleared on the next reset. These pins should not be jumpered for normal operation. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 22: Back Panel Connectors

    Network connection in place Blinking Amber Transmit/receive activity Right 10 Mbps connection (if left LED is on or blinking) Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 23: Hardware Requirements

    "Additional Information and Software." Memory The Server Board SE7230NH1-E provides four DIMM sockets across two channels, Channel A and Channel B. Channel A consists of DIMM sockets 1A and 2A. Channel B consists of DIMM sockets 1B and 2B.
  • Page 24: Power Supply

    Hard Disk Drives The Server Board SE7230NH1-E supports up to four SATA devices. See the documentation included with your server chassis for additional drive information and drive installation instructions. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 25: Server Utilities

    If a value cannot be changed for any reason, the feature’s value field is inaccessible. Table 4 describes the keyboard commands you can use in the BIOS Setup menus. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 26: Table 4. Keyboard Commands

    “No” is selected and the Enter key is pressed, or the ESC key is pressed, the user is returned to where they were before F10 was pressed without affecting any existing values. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 27: Upgrading The Bios

    Note: Review the instructions and release notes that are provided in the readme file distributed with the BIOS image file before attempting a BIOS upgrade. The release notes contain critical information regarding jumper settings, specific fixes, or other information to complete the upgrade. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 28: Upgrading The Bios

    4. Disconnect the AC power and return the CMOS Clear jumper to the Normal location, covering pins 1 and 2. 5. Close the server chassis, reconnect the AC power, and power up the system. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
  • Page 29: Hardware Installations And Upgrades

    3). DDR DIMMs will not physically fit into a server board designed to support DDR2 DIMMs (see letter “B” in Figure Figure 3. DDR vs. DDR2 DIMMs ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 30: Installing Dimms

    11. Replace the server's cover and reconnect the AC power cord. See the documentation that came with your server chassis for instructions on installing the server's cover. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 31: Removing Dimms

    3. Disconnect the AC power cord from the server. 4. Remove the server's cover. See the documentation that came with your server chassis for instructions on removing the server's cover. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 32: Figure 5. Lift Processor Socket Lever

    6). Open the load plate as shown (see letter “B” in Figure Do not touch the processor socket contacts (see Figure 6).. Figure 6. Lift Processor Load Plate ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 33: Figure 7. Removing Protective Processor Cover

    9. Grasp the socket protective cover tab and pull away from the load plate (see letter “A” Figure 9). Remove the socket protective cover and store for future use (see letter “B” in Figure TP01788 Figure 9. Removing the Socket Protective Cover ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 34: Installing The Active Heat Sink

    (see letter “B” in Figure 11). The snaps go through the holes in the server board. 3. Press downward on top of each cap (see letter “C” in Figure 11). ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 35: Installing The Passive Heat Sink

    Installing the Passive Heat Sink If your server board is installed into the Intel Server Platform SR1475NH1-E, a custom copper 1U passive heat sink is installed. The heat sink must be installed with the solid copper sides of it facing to the left and to the right of the chassis.
  • Page 36: Removing A Processor

    Do not force the heat sink from the processor. Doing so could damage the processor. 9. Lift the processor lever. 10. Press the release button and lift the load plate. 11. Remove the processor. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 37: Replacing The Backup Battery

    Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 38: Figure 13. Removing The Battery

    8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run Setup to restore the configuration settings to the RTC. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 39: Troubleshooting

    In addition to the server firmware and files, also update any drivers used for components you have installed in your system, such as video drivers, network drivers, and SCSI drivers. Intel provides a package called the “Platform Confidence Test” that may help with your diagnostics. See “Additional Information and Software”...
  • Page 40: Hardware Diagnostic Testing

    Turn on the video monitor. Set its brightness and contrast controls to at least two thirds of their maximum ranges (see the documentation supplied with your video display monitor). ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 41: Verifying Proper Operation Of Key System Lights

    9. The bootable CD-ROM is not detected. Try the solutions below in the order given. If you cannot correct the problem, contact your service representative or authorized dealer for help. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 42: Power Light Does Not Light

    8. Remove all add-in cares and see if the video returns. If successful, add the cards back in one at a time with a reboot between each addition. 9. Make sure the memory DIMMs comply with the system requirements. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 43: Characters Are Distorted Or Incorrect

    4. Have any of the fan motors stopped? Use the server management subsystem to check the fan status. 5. Have your fans speeded up in response to an overheating situation? ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 44: Diskette Drive Activity Light Does Not Light

    6. Make sure the correct networking software is installed. 7. If you are directly connecting two servers (without a hub), you will need a crossover cable. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 45: Problems With Network

    Before installing a PCI card, you should always: 1. Turn off the server power by using the power button on the front of the system. 2. Unplug the AC power cord(s) from the server. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 46: Problems With Newly Installed Application Software

    ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 47: Devices Are Not Recognized Under Device Manager

    Devices are not Recognized under Device Manager The Windows* operating systems do not include all of the drivers for the Intel chipsets, onboard NICs, and other components. See “Additional Information and Software” for a link to the current drivers and chipset files.
  • Page 48: Bios Post Beep Codes

    Replace or reseat the system video add-in card. If on-board video is bing used, the server board may be faulty. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 49: A Getting Help

    Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). ® Before calling, fill out an “Intel...
  • Page 50 Costa Rica .. Contact AT&T USA at 0 800 0 114 114. Once connected, dial 800 843 4481 Panama ..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 51 Argentina..Contact AT&T USA at 0-800 222 1288. Once connected, dial 800 843 4481 Paraguay..001 916 377 0114 Peru .... 001 916 377 0114 Uruguay..001 916 377 0114 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 52 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 53: B Safety Information

    To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 54: Intended Application Uses

    To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 55: System Access Warnings

    Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 56: Rack Mount Warnings

    Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 57: Other Hazards

    Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 58: Sicherheitshinweise Für Den Server

    Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
  • Page 59: Zielbenutzer Der Anwendung

    Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 60 Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 61: Warnhinweise Für Den Systemzugang

    Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 62: Elektrostatische Entladungen (Esd)

    Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 63: Andere Gefahren

    Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 64: Français

    Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
  • Page 65: Domaines D'utilisation Prévus

    Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 66 Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 67 Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 68: Décharges Électrostatiques†(Esd)

    Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 69: Autres Risques

    Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 70: Información De Seguridad Del Servidor

    Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
  • Page 71: Aplicaciones Y Usos Previstos

    Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 72 CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 73: Advertencias El Acceso Al Sistema

    Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 74: Descarga Electrostática (Esd)

    Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 75 No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 76 表示如果无视此“? ? ? 项”? ? ? ? ? ? ? 轻微人身伤害或财产损失的危险。 警告 表示如果无视此“? ? ”? ? ? ? ? ? ? 严重人身伤害的危险。 表示如果无视所示信息,即存在潜在的危险。 表示如果不遵守安全指导,存在可导致严重伤害或死亡的电击危险。 表示灼热组件或表面。 表示请勿触摸风机叶片,否则可能致伤。 表示拔下所有交流电线,断开交流电源 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 77 线路与调制解调器之间的连接。 • 提供正确接地的墙壁插座。 • 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: • 移举设备时遵守当地的职业健康与安全要求。 • 借助机械手段或其他合适的手段移举设备。 • 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接 通电源,就存在 5V 待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能 不止使用一根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除 任何热插拔组件之前,确保交流电线已拔下。 若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都 需要一根单独的交流电线。 本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设 备包含非常危险的电压级、电流级和能量级。请与生产商联系维修事宜。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其 从服务器上移除。 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 78 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: • 关闭所有与本产品相连的外设。 • 按下电源按钮至关闭状态,关闭系统。 • 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 • 断开与系统相连的所有线缆和通信线路。 • 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 • 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维修事宜. • 增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线 。 • 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线 ,然后再从服务器上移除电源供应设备。 注意事项 如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加 或移除热插拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中 接触灼热组件,移除或安装热插拔组件时务须小心。 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 79 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要 使用主板包装。请勿将主板在任何表面上滑动。 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 80 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的 电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行 系统可能导致系统部件受损。安装机箱盖的步骤如下: 首先检查并确保系统内没有遗留的未固定工具或部件。 • 检查线缆、内插板和其他组件已正确安装。 • 按产品说明安装机箱盖。 • 激光外设或激光设备 注意事项 为避免幅射暴露和 / 或人身伤害: 请勿打开任何激光外设或激光设备的外壳 • 激光外设或激光设备为非用户维修设备 • 请与生产商联系维修事宜 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 81: C Regulatory And Compliance Information

    Product EMC Compliance - Class A Compliance Note: Legally this product is required to comply with Class A emission requirements as it is intended for a commercial type market place. Intel targets 10db margin to Class A Limits. ® The Intel...
  • Page 82: Certifications / Registrations / Declarations

    Regulatory Country Marking Compliance UL Mark USA/Canada CE Mark Europe FCC Marking (Class A) EMC Marking (Class A) Canada CANADA ICES-003 CLASS A CANADA NMB-003 CLASSE A ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 83: Electromagnetic Compatibility Notices

    Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 84: Industry Canada (Ices-003)

    CE Mark to illustrate its compliance. Taiwan Declaration of Conformity (BSMI) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 85: Korean Compliance (Rrl)

    Korean Compliance (RRL) English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
  • Page 86 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 87: D Intel ® Server Issue Report Form

    ® Intel Server Issue Report Form Note: An on-line / automatic submission version of this form is available at http:// support.intel.com/support/motherboards/server/SE7230NH1-E/. For the fastest service, please submit your form via the Internet. Date Submitted: _______________________________________________________ Company Name: ______________________________________________________ Contact Name: ________________________________________________________...
  • Page 88 PCI-X (64bit/ 100MHz) (Slot 5) PCI Express* x8 (x8 Lane - Slot 6) Full-height Riser PCI Riser Slot Video On-board Video Add-in Video On-Board NIC1 On-Board NIC2 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 89 Hard Drive Information Drive Type (SCSI, Hot-swap or Make/Model SATA, etc) Fixed Revision Management Information On-Board Platform Instrumentation only ___________________________________ ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
  • Page 90 ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...

This manual is also suitable for:

Sr1475nh1-e

Table of Contents