Sign In
Upload
Manuals
Brands
Intel Manuals
Server Board
D50TNP
Intel D50TNP Manuals
Manuals and User Guides for Intel D50TNP. We have
1
Intel D50TNP manual available for free PDF download: Integration And Service Manual
Intel D50TNP Integration And Service Manual (233 pages)
Brand:
Intel
| Category:
Server Board
| Size: 22.26 MB
Table of Contents
Table of Contents
8
1 Introduction
19
Reference Documents and Support Collaterals
20
Table 1. Intel® Server D50TNP Family Reference Documents and Support Collaterals
20
2 L6 Integrated System - Essential System Component Installation
22
Table 2. Intel® D50TNP Module Family
22
Figure 1. System Directional Reference
23
Air Duct Removal / Installation
24
Air Duct Removal
24
Air Duct Installation
24
Figure 2. Removing the Air Duct
24
Figure 3. Installing the Air Duct
24
Opening and Closing Storage Module (Ipc - D50TNP2MHSTAC)
25
Opening the Top Tray
25
Figure 4. Removing the Air Duct
25
Closing the Top Tray
26
2.3 Processor Assembly and Installation
26
Figure 5. Removing the Air Duct
26
Figure 6. 1U Supported Standard Processor Heat Sinks
26
Figure 7. 1U Supported EVAC Processor Heat Sinks
27
Figure 8. 2U Heat Sinks
27
Assembly and Installation for Standard Air-Cooled Heat Sinks
28
Figure 9. 1U Heat Sinks Installed in Module
28
Figure 10. Processor Components and Processor Socket Reference Diagram with Standard Heat Sink
29
Figure 11. Installing the Processor Carrier Clip Onto the Processor - Part 1
30
Figure 12. Installing the Processor Carrier Clip Onto the Processor - Part 2
30
Figure 13. Removing the Heat Sink from Its Packaging
31
Figure 14. Processor Heat Sink Anti-Tilt Wires in the Outward Position
31
Figure 15. Pin 1 Indicator of Processor Carrier Clip
32
Figure 16. Socket Protective Cover Removal
32
Figure 17. PHM Alignment with the Socket Assembly
33
Figure 18. PHM Installation Onto the Server Board
33
Assembly and Installation for EVAC Heat Sinks
34
Figure 19. Tighten Heat Sink Fasteners
34
Figure 20. Processor Components and Processor Socket Reference Diagram with EVAC Heat Sink
35
Figure 21. Installing the Processor Carrier Clip Onto the Processor - Part 1
36
Figure 22. Installing the Processor Carrier Clip Onto the Processor - Part 2
36
Figure 23. Removing the Heat Sink from Its Packaging
37
Figure 24. Processor Heat Sink Anti-Tilt Wires in the Outward Position
37
Figure 25. Pin 1 Indicator of Processor Carrier Clip
38
Figure 26. Removing a Riser Assembly
38
Figure 27. Socket Protective Cover Removal
39
Figure 28. PHM Alignment with the Socket Assembly
40
Figure 29. PHM Installation Onto the Server Board
40
Figure 30. Tighten EVAC Heat Sink Extension
41
Figure 31.Installing a Riser Assembly
41
Assembly and Installation for Liquid-Cooled Configurations
42
Figure 32. Installing Processor Carrier Clip Onto Processor - Part 1
42
Figure 33. Installing Processor Carrier Clip Onto Processor - Part 2
43
Figure 34. Socket Protective Cover Removal
43
Figure 35. Align Processors and Processor Carrier Clips with Sockets
44
Figure 36. Screws to be Removed before the Installation
44
Liquid-Cooling Loop Installation (for Compute Module Ipc - D50TNP1MHCRLC)
44
Figure 37. Liquid-Cooling Loop Components
45
Figure 38. Removing Front VR Cooling Block's Protective Covers
46
Figure 39. Installing Front VR Blocks
47
Figure 40. Assembling the Manual Applicator
47
Figure 41. Applying Center VR Thermal Gap Filler
48
Figure 42. Installing Liquid-Cooling Loop
49
Figure 43. Securing the Processor Cold Plates
50
Figure 44. Removing Liquid-Cooling Loop Carrier
50
Figure 45. Securing Conduction Plate
51
Figure 46. Securing the Quick Disconnect Block and Memory Cooler
51
Memory (DIMM) Installation
52
DIMM Installation for Air-Cooled Modules
52
Figure 47. DIMM Blank Removal
52
Figure 48. DIMM Installation
53
DDR4 DIMM Installation for Liquid-Cooled Modules
54
Figure 49.Loosen Memory Cooler Screws
54
Figure 50. Memory Replacement Tools and Retention Clip
54
Figure 51. Installing the DDR4 DIMM in a Liquid-Cooled System
55
Figure 52. Installing the DDR4 DIMM Retention Clips
55
Figure 53. Securing the Memory Cooler to the Server Board
56
Figure 54. Installing a Module
56
Figure 55. Removing the Internal Chassis Rail
57
Figure 56. Installing the Internal Chassis Rail
57
Storage Module Installation (Ipc - D50TNP2MHSTAC Only)
57
Module Installation
56
3 System Options / Accessory Kit Installation
58
Figure 57. System Directional Reference
58
Installing the Chassis into a Rack
59
Installing the Fixed Rail Kit
59
Figure 58. Securing the Front of the Rack Rail
59
Installing the Chassis into a Rack
60
Figure 59. Securing the Back of the Rail
60
Figure 60. Installing the Chassis into the Rack
60
Module Removal / Installation
61
Module Removal
61
Figure 61. Removing a Module
61
Module Installation
62
Figure 62. Installing a Module
62
Figure 63. Removing the Internal Chassis Rail
63
Figure 64. Installing the Internal Chassis Rail
63
Air Duct Removal / Installation
64
Air Duct Removal
64
Air Duct Installation
64
Figure 65. Removing the Air Duct
64
Figure 66. Installing the Air Duct
64
Opening and Closing Storage Module (Ipc - D50TNP2MHSTAC)
65
Opening the Top Tray
65
Figure 67. Removing the Air Duct
65
Closing the Top Tray
66
Add-In Card Option Installation
66
Figure 68. Removing the Air Duct
66
Figure 69. 1U Riser Assembly and Riser Card Features (D50TNP1MHCPAC and D50TNP2MHSTAC)
67
Figure 70. 1U Riser Assembly and Riser Card Features (D50TNP1MHCRAC, D50TNP1MHCRLC, and D50TNP1MHEVAC)
67
Figure 71. 2U Riser Assembly and Riser Card Features (D50TNP2MHSVAC and D50TNP2MFALAC)
67
Figure 72. Removing a Riser Assembly
68
Figure 73. Installing an Add-In Card
68
Pcie* Add-In Card Installation
68
Riser Assembly Removal
68
Figure 74. Installing a Riser Assembly into the Chassis
69
Riser Assembly Installation
69
Figure 75. Mellanox Liquid Cooled Add-In Card with Thermal Pad
70
Figure 76. Installing the Mellanox Add-In Card Foam Pads
70
Liquid-Cooled Mellanox Add-In Card Installation (for Compute Module Ipc - D50TNP1MHCRLC)
70
Accelerator Module Add-In Card Installation (Ipc - D50TNP2MFALAC Only)
71
Figure 77. Air-Cooled Accelerator Module
71
Figure 78. Accelerator Module Riser Assembly
71
Figure 79. Accelerator Module Riser Card 1 - Front View
72
Figure 80. Accelerator Module Riser Card 2 - Front View
72
Figure 81. Removing a Riser Assembly
73
Figure 82. Removing the Bracket from the Chassis
73
Figure 83. Removing the Inside Screw for Oculink Cables
74
Figure 84. Removing the Oculink Cables
74
Figure 85. Removing the Riser Card Power Cables
75
Figure 86. Removing the Accelerator Module Riser Assembly
75
Figure 87. Replacing the Add-In Card Metal Bracket
76
Figure 88. Installing the Accelerator Add-In Card in the Riser Assembly
76
Figure 89. Securing the Accelerator Add-In Card in the Riser Assembly
77
Figure 90. Installing the Accelerator Module Riser Assembly
77
Figure 91. Connecting the Riser Card Power Cables
78
Figure 92. Connecting the Add-In Card Power Cable
78
Figure 93. Installing the Oculink Cables
79
Figure 94. Installing the Inside Screws for Oculink Cables
79
Figure 95. Installing the Bracket on the Chassis
80
Figure 96. Installing Riser Assembly into the Chassis
80
Drive Carrier Extraction, Assembly, and Installation
81
Drive Carrier Extraction
81
Figure 97. Drive Carrier Extraction from the Chassis
81
Drive Carrier Assembly
82
Figure 98. 2.5" Drive Carrier Assembly - Drive / Blank Removal
82
Figure 99. 2.5" Drive Carrier Assembly - Drive Installation into the Carrier
82
Drive Carrier Installation
83
Figure 100. 2.5" Drive Carrier Assembly - Alignment Features
83
Figure 101. Drive Carrier Installation into the Chassis
83
M.2 Storage Devices Installation
84
M.2 SSD Installation for Air-Cooled Configurations
84
Figure 102. Installing Air-Cooled M.2 SSD
84
Air-Cooled M.2 Heat Sink Installation
85
M.2 SSD Installation for Liquid-Cooled Configurations
85
Figure 103. Installing Air-Cooled M.2 Heat Sink
85
Figure 104. Installing the Thermal Interface Material (TIM) on M.2 SSD
85
M.2 Cold Plate Installation - Liquid-Cooled Configurations Only
86
Figure 105. Installing the M.2 SSD
86
Figure 106. Installing the M.2 Cold Plate
86
EDSFF Nvme* Extraction and Installation (Ipc - D50TNP2MHSTAC Only)
87
EDSFF Drive Extraction
87
EDSFF Drive Installation
87
Figure 107. EDSFF Drive Extraction from the Chassis
87
Figure 108. EDSFF Drive Installation into the Chassis
87
3.11 Intel® Virtual RAID on CPU (Intel® VROC) Upgrade Key Installation
88
3.12 Trusted Platform Module (TPM) Installation
88
Figure 109. Installing the Intel® VROC Upgrade Key
88
Figure 110. Installing the Trusted Platform Module (TPM)
88
Ethernet Management Port Module (EMP Module) (Ipc - AXXFCEMP)
89
Figure 111. Removing the EMP Blank
89
Figure 112. Installing the EMP Module/Blank
89
4 System Software Updates and Configuration
90
Using the BIOS Setup Utility
90
Entering BIOS Setup
90
No Access to the BIOS Setup Utility
90
Navigating the BIOS Setup Utility
90
Table 3. BIOS Setup: Keyboard Command Bar
91
5 System Packaging Assembly Instructions
92
6 System / Module - Features Overview
96
System Feature Identification
96
Figure 113. Module Identification for Four-Module System Configuration
96
Figure 114. Module Identification for Two-Module System Configuration
96
Figure 115. Module Identification for Three-Module System Configuration
96
Figure 116. Module Identification for One-Module System Configuration
97
Figure 117. Liquid-Cooled System Back View
97
Figure 118. Air-Cooled System Back View
97
Front Panel Features
98
Figure 119. 1U Compute Module Front Panel Feature Identification
98
Figure 120. 2U Management Module Front Panel Feature Identification
98
Figure 121. 2U Storage Module Front Panel Feature Identification
98
Front Control Panel Features
99
Figure 122. 2U Accelerator Module Front Panel Feature Identification
99
Figure 123. Front Control Panel Features
99
Figure 124. I/O Breakout Cable Connector Identification
99
System Component Identification
100
Figure 125. Server Chassis Component Identification
100
Figure 126. 1U Liquid-Cooled Compute Module Component Identification
101
Figure 127. 1U Air-Cooled Compute Module Component Identification
101
Figure 128. 2U Management Module Component Identification
102
Figure 129. 2U Storage Module Component Identification
102
Server Board Features
103
Figure 130. 2U Accelerator Module Component Identification
103
Figure 131. Intel® Server Board D50TNP1SB Feature Identification
103
Figure 132. Intel® Server Board D50TNP1SBCR Feature Identification
104
Figure 133. Onboard LED Location
104
7 FRU Replacement
105
Module Removal / Installation
106
Module Removal
106
Module Installation
106
Figure 134. Removing a Module
106
Figure 135. Installing a Module
107
Figure 136. Removing the Internal Chassis Rail
108
Figure 137. Installing the Internal Chassis Rail
108
Air Duct Removal / Installation
109
Air Duct Removal
109
Air Duct Installation
109
Figure 138. Removing the Air Duct
109
Figure 139. Installing the Air Duct
109
Opening and Closing Storage Module (Ipc - D50TNP2MHSTAC)
110
Opening the Top Tray
110
Figure 140. Removing the Air Duct
110
Closing the Top Tray
111
Processor Replacement
111
Processor Replacement for Standard Air-Cooled Heat Sinks
111
Figure 141. Removing the Air Duct
111
Figure 142. Processor Heat Sink Handling
112
Figure 143. PHM Assembly Removal from Processor Socket
112
Figure 144. Reinstall the Socket Cover
113
Figure 145. Processor Removal from PHM Assembly
113
Figure 146. Processor Carrier Clip Removal from PHM Assembly
114
Figure 147. Installing Processor Carrier Clip Onto Processor - Part 1
114
Figure 148. Installing Processor Carrier Clip Onto Processor - Part 2
115
Figure 149. Processor Heat Sink Handling
115
Figure 150. Processor Heat Sink Anti-Tilt Wires in the Outward Position
116
Figure 151. Pin 1 Indicator of Processor Carrier Clip
116
Figure 152. Socket Protective Cover Removal
117
Figure 153. PHM Alignment with Socket Assembly
117
Figure 154. PHM Installation Onto Server Board
118
Figure 155. Tighten Heat Sink Fasteners
118
Processor Replacement for EVAC Heat Sinks
119
Figure 156. Processor Heat Sink Handling
119
Figure 157. Removing a Riser Assembly
120
Figure 158. Loosen EVAC Heat Sink Fasteners
120
Figure 159. PHM Assembly Removal from Processor Socket
121
Figure 160. Reinstall the Socket Cover
122
Figure 161. Processor Removal from PHM Assembly
122
Figure 162. Processor Carrier Clip Removal from PHM Assembly
123
Figure 163. Installing Processor Carrier Clip Onto Processor - Part 1
123
Figure 164. Installing Processor Carrier Clip Onto Processor - Part 2
124
Figure 165. Processor Heat Sink Handling
124
Figure 166. Processor Heat Sink Anti-Tilt Wires in the Outward Position
125
Figure 167. Pin 1 Indicator of Processor Carrier Clip
125
Figure 168. Socket Protective Cover Removal
126
Figure 169. PHM Alignment with Socket Assembly
126
Figure 170. PHM Installation Onto Server Board
127
Figure 171. PHM Installation Onto Server Board
127
Processor Replacement for Liquid-Cooled Configurations
128
Figure 172.Installing a Riser Assembly
128
Figure 173. Loosening Processor Cold Plate Nuts
129
Figure 174. Removing Processor Cold Plate
129
Figure 175. Reinstall the Socket Cover
130
Figure 176. Processor Removal from Processor Carrier Clip and Processor Cold Plate
130
Figure 177. Processor Carrier Clip Removal from Processor Cold Plate
131
Figure 178. Installing Processor Carrier Clip Onto Processor - Part 1
131
Figure 179. Installing Processor Carrier Clip Onto Processor - Part 2
132
Figure 180. Socket Protective Cover Removal
132
Figure 181. Processor Installation Onto Server Board
133
Figure 182. Assembling the Manual Applicator
133
Figure 183. Applying Center VR Thermal Gap Filler
134
Figure 184. Reinstalling Processor Cold Plate
134
Memory (DIMM) Replacement
135
DIMM Replacement for Air-Cooled Modules
135
Figure 185. Securing Processor Cold Plate
135
Figure 186. Removing the DIMM from an Air-Cooled System
136
Figure 187. Installing the DIMM in an Air-Cooled System
136
DDR4 DIMM Replacement for Liquid-Cooled Modules
137
Figure 188. Memory Replacement Tools and Retention Clip
137
Figure 189. Loosen Memory Cooler Mounting Screws
137
Figure 190. Removing the DIMM Retention Clips
138
Figure 191. Removing the DIMM from a Liquid-Cooled System
138
Figure 192. Installing the DIMM in a Liquid-Cooled System
139
Figure 193. Installing the DIMM Retention Clips
139
Memory Heat Spreader Thermal Pad Replacement (Liquid-Cooled Modules Only)
140
Figure 194. Securing the Memory Cooler to the Server Board
140
Figure 195. Removing a Thermal Pad
141
Figure 196. Installing a Thermal Pad
141
M.2 Storage Devices Replacement
142
M.2 and Heat Sink Replacement for Air-Cooled Configurations
142
Figure 197. Removing Air-Cooled M.2 Heat Sink
142
Figure 198. Removing Air-Cooled M.2 SSD
142
Figure 199. Installing Air-Cooled M.2 SSD
143
Figure 200. Installing Air-Cooled M.2 Heat Sink
143
M.2 SSD and Cold Plate Replacement for Liquid-Cooled Configurations
144
Figure 201. Removing the Liquid-Cooled M.2 Cold Plate
144
Figure 202. Removing Liquid-Cooled M.2 SSD
144
Figure 203. Installing Liquid-Cooled M.2 SSD
145
Figure 204. Installing the M.2 SSD
145
Riser Assembly Replacement
146
Figure 205. Installing Liquid-Cooled M.2 Cold Plate
146
Figure 206. 1U Riser Assembly and Riser Card Features (D50TNP1MHCPAC and D50TNP2MHSTAC)
147
Figure 207. 1U Riser Assembly and Riser Card Features (D50TNP1MHCRAC D50TNP1MHCRLC, and D50TNP1MHEVAC)
147
Figure 208. 2U Riser Assembly and Riser Card Features (D50TNP2MHSVAC and D50TNP2MFALAC)
147
Figure 209. Removing a Riser Assembly
148
Figure 210. Add-In Card Removal
148
Pcie* Add in Card Replacement
148
Riser Assembly Removal
148
Figure 211. Add-In Card Installation
149
Figure 212. Installing a Riser Assembly
149
Riser Assembly Installation
149
Liquid-Cooling Loop Replacement (for Compute Module Ipc - D50TNP1MHCRLC)
150
Figure 213. Liquid-Cooling Loop Components
150
Figure 214. Removing the Screws on Quick Disconnect Block and Memory Cooler
151
Figure 215. Removing the Screws on the Conduction Plate
151
Figure 216. Installing the Liquid-Cooling Loop Carrier
152
Figure 217. Loosening Processor Cold Plates
152
Figure 218. Removing Liquid-Cooling Loop
153
Figure 219. Align Processors and Processor Carrier Clips with Sockets
153
Figure 220. Removing Front VR Cooling Blocks
154
Figure 221. Removing Front VR Cooling Blocks Protective Covers
155
Figure 222. Installing Front VR Blocks
155
Figure 223. Assembling the Manual Applicator
156
Figure 224. Applying Center VR Thermal Gap Filler
156
Figure 225. Installing Liquid-Cooling Loop
157
Figure 226. Securing the Processor Cold Plates
157
Figure 227. Removing the Liquid-Cooling Loop Carrier
158
Figure 228. Securing the Conduction Plate
158
Mellanox Add-In Card Replacement (for Compute Module Ipc - D50TNP1MHCRLC)
159
Figure 229. Securing the Quick Disconnect Block and Memory Cooler
159
Figure 230. Mellanox Liquid Cooled Add-In Card with Thermal Pad
160
Figure 231. Installing the Mellanox Add-In Card Foam Pads
160
Accelerator Module Add-In Card Replacement (Ipc - D50TNP2MFALAC Only)
161
Figure 232. Removing a Riser Assembly
161
Figure 233. Removing the Bracket from the Chassis
161
Figure 234. Removing the Inside Screw for Oculink Cables
162
Figure 235. Removing the Oculink Cables
162
Figure 236. Disconnecting the Riser Card Power Cables
163
Figure 237. Disconnecting Add-In Power Cable
163
Figure 238. Removing the Accelerator Module Riser Assembly
164
Figure 239. Lifting the Flap up on the Front Side of the Riser Assembly
164
Figure 240. Detaching the Accelerator Add-In Card from the Riser Assembly
165
Figure 241. Removing the Accelerator Add-In Card from the Riser Assembly
165
Figure 242. Replacing the Add-In Card Metal Bracket
166
Figure 243. Installing the Accelerator Add-In Card in the Riser Assembly
166
Figure 244. Securing the Accelerator Add-In Card in the Riser Assembly
167
Figure 245. Installing the Accelerator Module Riser Assembly
167
Figure 246. Connecting the Riser Card Power Cables
168
Figure 247. Connecting Add-In Card Power Cable
168
Figure 248. Installing the Oculink Cables
169
Figure 249. Installing the Inside Screws for Oculink Cables
169
Figure 250. Installing the Bracket on the Chassis
170
Figure 251. Installing Riser Assembly into the Chassis
170
Accelerator Module Riser Card Replacement (Ipc - D50TNP2MFALAC Only)
171
Figure 252. Accelerator Riser Assembly Rear Bracket Removal
171
Figure 253. Accelerator Riser Card Removal
171
Figure 254. Accelerator Riser Card Installation
172
Figure 255. Accelerator Riser Assembly Rear Bracket Installation
172
Accelerator Module Power Connector Board Replacement (Ipc - D50TNP2MFALAC Only)
173
Figure 256. Accelerator Module Power Connector Board Removal
173
Figure 257. Accelerator Module Power Connector Board Installation
174
7.14 Intel® Virtual RAID on CPU (Intel® VROC) Upgrade Key Replacement
175
7.15 Trusted Power Module (TPM) Replacement
175
Figure 258. Removing the Intel® VROC Upgrade Key
175
Figure 259. Installing the Intel® VROC Upgrade Key
175
Figure 260. Removing the Trusted Platform Module (TPM)
176
Figure 261. Installing the Trusted Platform Module (TPM)
176
7.16 Power Supply Replacement
177
Figure 262. Removing the Power Supply
177
Figure 263. Installing the Power Supply
177
7.17 Server Board Replacement
178
Figure 264. Server Board Removal
178
Figure 265. Server Board Installation
179
7.18 System Fan Replacement
180
Figure 266. System Fan Configuration - Liquid-Cooled System
180
Figure 267. System Fan Configuration - Air-Cooled System
180
Figure 268. Removing the System Fan
181
Figure 269. Installing the System Fan
181
Chassis Plumbing Assembly Replacement (Liquid-Cooled Systems Only)
182
Figure 270. Removing the Quick Connect Fillers
182
Figure 271. Removing the Quick Connect Screws
183
Figure 272. Removing Quick Connect Covers
183
Figure 273. Removing the Back Cover
183
Figure 274. Removing the Chassis Plumbing Assembly
184
Figure 275. Installing the Chassis Plumbing Assembly
185
Figure 276. Installing Quick Connect Covers
186
Figure 277. Securing the Quick Connect Couplings to the Covers
186
Figure 278. Installing the Quick Connect Fillers
187
Figure 279. Securing the Back Cover
187
7.20 Power Distribution Board (PDB) Assembly Replacement
188
Figure 280. Removing the Back Cover
188
Figure 281. Disconnecting the System Fan Power Cables
189
Figure 282. Removing the Power Distribution Board
190
Figure 283. Installing the Power Distribution Board
191
Figure 284. Connecting System Fan Power Cables
192
Figure 285. Securing the Back Cover
192
7.21 Internal Chassis Rail Replacement
193
Figure 286. Removing the Internal Chassis Rail
193
7.22 System Battery Replacement
194
Figure 287. Installing the Internal Chassis Rail
194
Figure 288. Removing the System Battery
194
Figure 289. Installing the System Battery
195
Appendix A. Getting Help
196
Appendix B. Memory Population Rules
197
DDR4 DIMM Population Rules
197
Intel® Optane™ Persistent Memory 200 Series Module Rules (Intel® Server Board D50TNP1SB Only)
197
Table 4. Intel® Optane™ Persistent Memory 200 Series Module Support
198
Table 5. Standard DDR4 Dimms Compatible with Intel® Optane™ Pmem Modules
198
Appendix C. System Status LED State Definitions
199
Figure 290. Front Control Panel Features
199
Table 6. Power / Sleep LED Functional States
199
Table 7. Intel® D50TNP Module Status LED State Definitions
200
Appendix D. Onboard Configuration and Service Jumpers
202
Figure 291. Reset and Recovery Jumper Block Location
202
BIOS Default Jumper (BIOS DFLT - J17)
203
Password Clear Jumper (PASSWD_CLR - J12)
203
Intel® Management Engine (Intel® ME) Firmware Force Update Jumper (ME_FRC_UPDT - J13)
204
BMC Force Update Jumper (BMC_FRC_UPDT - J2X4)
205
BIOS SVN Downgrade (Svn_Bypass - J16)
205
BMC SVN Downgrade (J33)
206
Appendix E. POST Code Diagnostic LED Decoder
207
Figure 292. Onboard POST Diagnostic Leds
207
Table 8. POST Progress Code LED Example
207
Early POST Memory Initialization MRC Diagnostic Codes
208
Table 9. MRC Progress Codes
208
Table 10. MRC Fatal Error Codes
209
BIOS POST Progress Codes
210
Table 11. POST Progress Codes
210
Appendix F. POST Error Codes
213
Table 12. POST Error Messages and Handling
214
Processor Initialization Error Summary
219
Table 13. Mixed Processor Configurations Error Summary
220
Appendix G. Product Safety - Multi-Language
221
Appendix H. Glossary
233
Advertisement
Advertisement
Related Products
Intel DBS1200BTS
Intel D5005
Intel D50DNP Series
Intel D50DNP1MHCPAC
Intel D50DNP1MHEVAC
Intel D50DNP1MHCPLC
Intel D50DNP2MHSVAC
Intel D50DNP1MFALLC
Intel D50DNP2MFALAC
Intel D5400XS - Desktop Board Extreme Series Motherboard
Intel Categories
Motherboard
Computer Hardware
Server
Server Board
Desktop
More Intel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL