Table 5-5 Edit Profile Prompts - Honeywell VRX180 User Manual

Honeywell video recorder user manual
Table of Contents

Advertisement

Prompt
RAMP TYPE
TIME UNITS
EDIT SEGMENTS
GUAR SOAK LO LIM
GUAR SOAK HI LIM
HYSTERESIS
BATCH FIRST
SEGMENT
BATCH LAST
SEGMENT

Table 5-5 Edit Profile Prompts

Range/Selections
VAL/DUR, TIME, RATE,
EXTERNAL
SECS, MINS, HOURS
OFF or number
OFF or number
OFF or number
0-63
0-63
Video Recorder – User Manual
Definition
See 4 types of ramp segments on page 178.
Select the time units to be used by all segments
of the profile.
See Table 5-6.
The profiler will Hold if PV #1 or PV #2 deviates
more than this much below the profiler output.
See Guaranteed Soak on page 182 for details.
The profiler will Hold if PV #1 or PV #2 deviates
more than this much above the profiler output.
See Guaranteed Soak on page 182 for details.
See Hysteresis on page 182 for details.
Specify the first segment of the batch phase.
Prior segments are the start-up phase. A value
of 0 indicates a single phase profile. See Two
types of profiles on page 177 for details.
Specify the last segment of the batch phase.
Segments after this segment are the shutdown
phase. A value of 0 indicates a single phase
profile. See Two types of profiles on page 177
for details.
Setpoint Profiler
(continued)
193