Input Impedance
Input Current
Minimum ON Current
Maximum OFF Current
Base Power Required*
OFF to ON Response
ON to OFF Response
Number
Isolation from ground
Switching Voltage
Switching Current
Number
Operating Voltage
Output Type
Peak Voltage
AC Frequency
Isolation from ground
Isolation between outputs
ON Voltage Drop
Maximum Load Current
Maximum Leakage Current
Maximum Inrush Current
Minimum Load
Base Power required*
OFF to ON Response
ON to OFF Response
Fuses (European type 5 x
20mm)
Number
Contact Rating
Isolation from ground
Isolation between outputs
Contact Type
* Base Power Required is the power required to provided module operation within specifications.
Table 1-1 Specifications (continued)
51K
0.9 mA @ 100 Vac
0.3 mA
0.15 mA
50 mA maximum
5 to 30 ms
10 to 50 ms
Logic Inputs
6 (dry contact) per module, up to 6 modules per video recorder
2300 Vac/1 min.
5 Vdc
5 mA
Digital Outputs
AC Outputs
6 per module, up to 6 modules per video
recorder. Only 1-5 on each module can
be configured as DAT outputs.
15 to 264 Vac
SSR (Triac)
264 Vac
47 to 63 Hz
2300 Vac/1 min.
350 Vac
<1.5 Vac (>0.1A)
<3.0 Vac (<0.1A)
0.5A per point
4 mA (264 Vac, 60 Hz)
1.2 mA (100 Vac, 60 Hz)
0.9 mA (100 Vac, 50 Hz)
10A for 10 ms
10 mA
20 mA/ ON pt. 250 mA
maximum
1 ms
1 ms +1/2 cycle
1 per output, 1.0A slow blow
Relay (Alarm) Outputs
6 per module, up to 6 modules per video recorder. Only 1-5 on each module can be
configured as DAT outputs.
2A, 250 Vac on resistive load
2300 Vac/1 min.
2300 Vac/1 min.
SPST normally open (NO), individually configurable to normally closed (NC) via
jumper
Video Recorder - User Manual
5.6K
1.1 mA @ 12 Vdc
3.2 mA @ 24 Vdc
0.3 mA
0.2 mA
50 mA maximum
1 to 8 ms
1 to 8 ms
DC Outputs
6 (current sinking) per module, up to 6
modules per video recorder. Only 1-5
on each module can be configured as
DAT outputs.
10.2 to 26.4 Vdc
NPN open collector
40 Vdc
N/A
1100 Vac/1 min.
30 Vac
1.5 Vdc maximum
0.3A per point
0.1 mA @ 40 Vdc
1A for 10 ms
0.5 mA
120 mA maximum
5V
1 ms
1 ms
1 per output
1A fast blow