Power Supply - Fujitsu PRIMERGY RX900 S2 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX900 S2:
Table of Contents

Advertisement

5

Power supply

V
CAUTION!
The server supports a mains voltage in the range of 200 - 240 V. You may
only operate the server if its rated voltage range corresponds to the local
mains voltage.
I
Phase redundancy is possible in regions, where a single phase provides
200 - 240V; in other regions with lower single phase voltage, two phases
must be coupled and complete phase redundancy thus is not possible.
In the basic configuration, the server is configured with three hot-plug power
supply units. This ensures 2 + 1 power supply redundancy. One additional hot-
plug power supply unit can be installed to achieve AC redundancy in a 2+2
configuration. For more information on the redundancy concept see
"PRIMERGY RX900 S2 Server Operating Manual".
V
CAUTION!
Areas around the power supply unit may remain extremely hot after
shutdown. Wait for a while after shutdown before removing the power
supply unit.
When installing the power supply unit, be sure to confirm that the
connector of the PSU is not damaged or bent.
Do not insert your hands in the power supply unit slot when removing
the power supply unit. Doing so may cause electric shock.
If the power supply unit is hard to remove, do not pull out it by force.
The power supply unit is heavy, so handle it carefully. If you drop it by
mistake, injuries may result.
RX900 S2
Upgrade and Maintenance Manual
53

Advertisement

Table of Contents
loading

Table of Contents