Display Console Initializes Then Fails; No Prompt Upon Release Of Start Key - Life Fitness Lifecycle 9100 Service Manual

Belt drive series
Hide thumbs Also See for Lifecycle 9100:
Table of Contents

Advertisement

---------~--
Lifecycle 9100 and 9500HR Series Exercise Bikes
TROUBLESHOOTING GUIDE
Malfunction
Probable Cause
Corrective Action
Display Console LEOs not
Pedaling to slowly
Pedal faster than 45 RPM then press the
illuminating
START button.
Kevoad not respondinQ
MassaQe kevoad with finQertips.
Insufficient battery voltage
Check battery voltage. The LC9500 has a
6VDC battery (non alkiline) which should test
out between 5.8 to 6.3 VDC. The LC91 00 has a
9VDC alkaline battery and it should test out
between (8.8 - 9.2VDC).
Loose wire connections
Disconnect then reconnect connections.
Worn or damaged wire
Inspect wire hamesses. Replace worn or
hamesses
damaged harness.
Malfunctioning display console
Test with substitute display console. Replace
malfunctioning display console.
Malfunctioning alternator
Test with substitute ACB. Replace
control board (ACB)
malfunctioninQ ACB.
Malfunctioning alternator
Test Alternator output or test with substitute
Alternator. Replace malfunctioning Alternator.
Refer to Alternator Voltage Test.
Display console initializes
Loose wire connections
Disconnect then secure connections.
then fails
Worn or darnaged wire
Inspect wire harnesses. Replace worn or
harnesses
damaged harness.
Malfunctioning display console
Test with substitute display console. Replace
malfunctioning display console.
Malfunctioning alternator
Test with substitute altemator control board.
control board
Replace malfunctioning board.
Malfunctioning alternator
Test alternator output or test with substitute
alternator. Replace malfunctioning altemator.
Refer to Alternator VoltaQe Test.
No prompt upon release of
Malfunctioning display console
Test with substitute display console. Replace
START key. Entry of
malfunctioning display console.
additional information not
allowed.
Malfunctioning alternator
Test with substitute ACB. Replace defective
control board
alternator control board.
Malfunctioning alternator
Test alternator output or test with substitute
alternator. Replace malfunctioning alternator.
Refer to Alternator VoltaQe Test.