Symptom: DISPLAY CONSOLE INITIALIZES BUT DOESN'T STAY ON
Symptom
Display Console initializes
but doesn't stay on
2
Probable Cause
Loose connection or damaged
harness
Defective Display Console
Defective Alternator Control
Board
Defective Alternator
Corrective Action
q
Reseat Connectors at Display Console,
Alternator Control Board, Alternator and
Battery
q
Check wire harnesses for damage
q
Switch Display Console
q
Switch Alternator Control Board
q
Switch Alternator
For Assistance Call: