Life Fitness Lifecycle 9100 Service Manual page 14

Belt drive series
Hide thumbs Also See for Lifecycle 9100:
Table of Contents

Advertisement

Lifecycle 9100 and 9500HR Series Exercise Bikes
TROUBLESHOOTING GUIDE
Malfunction
Probable Cause
Corrective Action
Display Console keys
Attempting to enter program
Refer to Operation Manual for program
(except START key) do not
not available.
availabilitv.
function and Exercise Bike
does not respond.
Keypad is cold
Massaoe keypad with finoertips.
Display Console connection
Test with substitute Display Console. Replace
loose
malfunctionino Display Console.
Malfunctioning Display Console
Test with substitute Display Console. Replace
malfunctionino Display Console.
Upon start of program,
Pedaling too slowly
Pedal faster than 45 RPM.
excessive resistance load
is immediate; no normal,
Insufficient battery voltage
Check battery voltage. The LC9500 has a
incremental increase from
6VDC battery (non alkiline) which should test
"no load."
out between 5.8 to 6.3 VDC. The LC91 00 has a
9VDC alkaline battery and it should test out
between (8.8 - 9.2VDC).
Loose wire connections
Disconnect then, reconnect connections.
Worn or damaged wire
Inspect wire harnesses. Replace worn or
harnesses
damaoed harness.
Malfunctioning Display Console
Test with substitute Display Console. Replace
malfunctioning Display Console.
Malfunctioning Alternator
Test with substitute Altemator Control Board.
Control Board
Replace malfunctionino board.
Malfunctioning Alternator
Test Alternator output or, test with substitute
Altemator. Replace malfunctioning Alternator.
Refer to Alternator Voltage Test.
During program, excessive
Pedalino too slowly
Pedal faster than 45 RPM.
resistance loading occurs.
Loose wire connections
Disconnect then, reconnect connections.
Worn or damaged wire
Inspect wire harnesses. Replace worn or
harnesses
damaged harness.
Malfunctioning Display Console
Test with substitute Display Console. Replace
malfunctioning Display Console.
Malfunctioning Alternator
Test with substitute ACB. Replace
Control Board (ACB)
malfunctionino ACB.
Malfunctioning Alternator
Test Alternator output or, test with substitute
Altemator. Replace malfunctioning Alternator.
Refer to Alternator Voltage Test.
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lifecycle 9500hr

Table of Contents