Displaying And Maintaining Rmon - 3Com Switch 4800G 24-Port Configuration Manual

Switch 4800g family 24-port, pwr 24-port, 48-port, pwr 48-port, 24-port sfp
Hide thumbs Also See for Switch 4800G 24-Port:
Table of Contents

Advertisement

944
C
76: RMON C
HAPTER
Displaying and
Maintaining RMON
ONFIGURATION
To do...
Create an entry in the private
alarm table
n
Two entries with the same configuration cannot be created. If the parameters
of a newly created entry are identical to the corresponding parameters of an
existing entry, the system considers their configurations the same and the
creation fails. Refer to Table 75 for the parameters to be compared for different
entries.
The system limits the total number of all types of entries. When the total
number of an entry reaches the maximum number of entries that can be
created, the creation fails.
When you create an entry in the history table, if the specified buckets number
argument exceeds the history table size supported by the device, the entry will
be created. However, the validated value of the buckets number argument
corresponding with the entry is the history table size supported by the device.
Table 75 Restrictions on the configuration of RMON
Entry
Event
History
Statistics
Alarm
Pri-alarm
To do...
Display RMON statistics
Display RMON history information
and the latest history sampling
information
Display RMON alarm configuration
information
Display RMON prialarm
configuration information
Display RMON events
configuration information
Use the command...
rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-interval { absolute |
changeratio | delta }
rising-threshold threshold-value1
event-entry1 falling-threshold
threshold-value2 event-entry2
entrytype { forever | cycle
cycle-period } [ owner text ]
Parameters to be compared
Event description (description string), event type (log, trap,
logtrap or none) and community name (trap-community or
log-trapcommunity)
Sampling interval (interval sampling-interval)
Only one statistics entry can be created on an interface.
Alarm variable (alarm-variable), sampling interval (sampling-interval),
sampling type (absolute or delta), rising threshold
(threshold-value1) and falling threshold (threshold-value2)
Alarm variable formula (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute, changeratio or
delta), rising threshold (threshold-value1) and falling threshold
(threshold-value2)
Use the command...
display rmon statistics
[ interface-type interface-number ]
display rmon history [ interface-type
interface-number ]
display rmon alarm [ entry-number ] Available in any
display rmon prialarm
[ entry-number ]
display rmon event [ entry-number ] Available in any
Remarks
Optional
Remarks
Available in any
view
Available in any
view
view
Available in any
view
view

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents