SWITCH NAME
SW0 (DIP SW)
ON
1 2 3 4 5 6 7 8
The figure in the SWITCH NAME column and the position in
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE:
When the power is on, disconnect the cables before unplugging the circuit card and
connect the cables after plugging the circuit card.
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 1.0
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
SWITCH
SETTING
NUMBER
POSITION
ON
1
OFF
ON
2
OFF
3
OFF
ON
4
OFF
ON
5
OFF
ON
6
OFF
7
OFF
ON
8
OFF
FUNCTION
No. 0
Forcibly turning the DTR
Circuit
signal to ON
The DTR signal from DTE
goes through the card
Forcibly turning the RTS/C
signal to ON
The RTS/C signal from
DTE goes through the
card
Not used
V.11 (X.21) interface
V.24/V.28 (RS-232C)
interface
No. 1
Forcibly turning the DTR
Circuit
signal to ON
The DTR signal from DTE
goes through the card
Forcibly turning the RTS/C
signal to ON
The RTS/C signal from
DTE goes through the
card
Not used
V.11 (X.21) interface
V.24/V.28 (RS-232C)
interface
in the SETTING POSITION
PN-2DPCB (DPC)
CHECK
Page 359