Maytag MLE20PRBZW1 Installation Instructions Manual page 24

Commercial stacked washer/dryer gas or electric
Table of Contents

Advertisement

Available languages

Available languages

ELECTRIC
DRYER
ELECTRICAL
CONNECTIONS
Connection
Options
Power Cord
4-wire receptacle (NEMA Type 14-30R)
Direct Wire
4-wire direct
(127
3-wire receptacle (NEMA Type 10-30R)
3-wire direct
(89 mn
Connecting
4-Wire
Connection:
Power
Supply
Cord
IMPORTANT: A 4-wire connection
is required where local
codes do not permit the use of 3-wire connections.
Standard
Power Supply
Cord
Connectors
Flanged spade connector
Ring Connector
Connecting
Ground and Neutral Wires
1. Remove center terminal block screw and the ground wire
by removing the external ground connector screw.
2. Connect ground and neutral wire to center terminal block.
24
Connecting
Direct
Wire
Ground
3. Connect ground wire (green or bare) with external ground
connector screw.
Connecting
Remaining Wires
4. Connect remaining wires with outer terminal block screws.