Downflow Return Air Configurations And Restrictions; Horizontal Return Air Configurations And Restrictions - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

(_
RETURN
AIR
RETURN
AIR
®
DOWNFLOW RETURN AIRCONFIGURATIONS
ANDRESTRiCTiONS
AIR FLOW MODELS
RETURN AIR
RETURN AIR
RETURN AIR
RETURN
AIR
CONNECTION
1
CONNECTION
2
CONNECTION
3
COMBINATIONS
ONLY
ONLY
ONLY
OF 1,2, AND 3
066.060, -22 AND
YES
NO
NO
NO
-20 MODELS
ALL OTHER MODELS
YES
NO
NO
NO
Fig. 19 -
Downflow
Return
Air Configurations
and Restrictions
A02163
RETURN
AIR
s
_
NOT
PERMITTED
FOR
066,060,
-22-20
AIR
FLOW
MODELS
II
III
II III
"l
II III
RET, #N
II III
=
SIDE
RETURN
AIR
b/ll©NOT
PERMITTED
FOR
IVI
066060
2_o ELS
I_ _l _VV
--
HORIZONAL
RETURN
RETURN
AIR
* NOTE:
RESTRICTION
_.
SAME
FOR
AIR
RESTRICTIONS
HORIEONAL
LEFT
T
\%
HORIZONTAL
RETURN AIR CONFIGURATIONS
AND RESTRICTIONS
AIR FLOW MODELS
RETURN AIR
RETURN AIR
RETURN AIR
RETURN AIR
CONNECTION
1
CONNECTION
2
CONNECTION
3
COMBINATIONS
ONLY
ONLY
ONLY
OF 1, 2, AND 3
066.060,
-22 AND
YES
NO
NO
NO
-20 MODELS
ALL OTHER MODELS
YES
YES
YES
YES
Fig. 20 -
Horizontal
Return
Air Configurations
and Restrictions
A02162
Upflow and Horizontal Furnaces
Connect supply-air
duct to flanges on furnace supply-air outlet.
Bend flange upward to 90 ° with wide duct pliers. (See Fig. 14.)
The supply-air
duct must be connected to ONLY the furnace
supply-outlet-air
duct flanges or air conditioning
coil casing
(when used). DO NOT cut main furnace casing side to attach
supply air duct, humidifier, or other accessories. All accessories
MUST be connected to duct external to furnace main casing.
NOTE:
For horizontal applications, the top-most flange may be
bent past 90 ° to allow the evaporator coil to hang on the flange
temporarily while the remaining attachment and sealing of the
coil are performed.
Downflow Furnaces
Connect supply-air
duct to supply-air
outlet on furnace. Bend
flange inward past 90 ° with wide duct pliers. (See Fig. 14.) The
supply-air
duct must be connected
to ONLY the furnace
supplyoutlet or air conditioning coil casing (when used). When
installed
on combustible
material,
supply-air
duct must be
connected to ONLY the factory-approved
accessory subbase or a
factory-approved
air conditioning coil casing. DO NOT cut main
furnace casing to attach supply side air duct, humidifier, or other
18