Multiple Orientations - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

THE BLOWER IS LOCATED
TOTHE RIGHT OFTHE
BURNER SECTION, AND
AIR CONDiTiONED
AiR IS
DISCHARGED TO THE LEFT.
THE BLOWER IS
LOCATED ABOVE THE
BURNER SECTION, AND
CONDITIONED
AIR IS
DISCHARGED
DOWNWARD
AIRFLOW
d>
THE BLOWER IS
LOCATED BELOW THE
BURNER SECTION, AND
CONDiTiONED
AIR IS
DISCHARGED
UPWARD.
t
\
HORIZONTAL
LEFT
_AIRFLOW
HORIZONTAL
RIGH-'_AIR FL_OW
Fig. 4 - Multipoise
Orientations
THE BLOWER IS
LOCATED TO THE LEFT
OF THE BURNER SECTION,
AND CONDiTiONED
AIR IS
DISCHARGED TO THE RIGHT.
A02097
be located
as close to the chimney
or vent and attached
to an air distribution
system. Refer to Air Ducts section.
be provided
ample space for servicing
and cleaning.
Always
comply
with minimum
fire protection
clear-
ances shown
on the furnace
clearance
to combustible
label.
The following
types of furnace
installations
may re-
quire OUTDOOR
AIR for combustion
due to chemical
exposures:
Commercial
buildings
Buildings
with indoor
pools
Laundry
rooms
Hobby or craft rooms,
and
Chemical
storage areas
If air is exposed
to the following
substances,
it should not be used
for
combustion
air,
and
outdoor
air
may
be
required
for
combustion:
Permanent
wave solutions
Chlorinated
waxes
and cleaners
Chlorine
based swimming
pool chemicals
Water softening
chemicals
De-icing
salts or chemicals
Carbon
tetrachloride
Halogen
type refrigerants
Cleaning solvents (such as perchloroethylene)
Printing inks, paint removers, varnishes, etc.
Hydrochloric acid
Cements and glues
Antistatic fabric softeners for clothes dryers
Masonry acid washing materials
All fuel-burning
equipment must be supplied with air for fuel
combustion.
Sufficient air must be provided to avoid negative
pressure in the equipment room or space. A positive seal must be
made between the furnace cabinet and the return-air
duct to
prevent pulling air from the burner area and from draft safeguard
opening.
FIRE
AND EXPLOSION
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
death, and/or property
damage.
When
the furnace
is installed
in a residential
garage,
the
burners
and ignition
sources
must
be located
at least
18
inches
above
the
floor.
The
furnace
must
be located
or
protected
to avoid damage
by vehicles.
When the furnace
is
installed
in
a public
garage,
airplane
hangar,
or other
building
having
a hazardous
atmosphere,
the furnace
must
be installed
in accordance
with the NFGC.
(See Fig. 5.)