Media Cabinet Filter Procedures; Blower Motor And Wheel - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

CUT HAZARD
Failure
to follow
this caution
may result in personal
iniury.
Sheet
metal parts may have sharp edges
or burrs.
Use care
and wear
appropriate
protective
clothing,
safety glasses
and
gloves
when handling
parts and servicing
furnaces.
Media
cabinet
filter procedures:
NOTE:
Media
cabinet
or 3/4-in.
(19
ram)
filter
rack
are
accessories
and are not included
from the factory.
1. Turn
off electrical
supply
to furnace
before
removing
filter
access door.
2. Remove
filter cabinet
door.
3. Slide filter out of cabinet.
4. If equipped
with permanent,
washable
3/4-in.
(19 ram) filter,
clean filter by spraying
cold tap water through
filter in opposite
direction
of airflow. Rinse filter and let dry. Oiling
or coating
of
the filter is not recommended.
See Table 14 for size information.
5. If equipped
with
factory-specified
disposable
media
filter,
replace
only with media
filter having
the same
part number
and
size. For expandable
replacement
media,
refer to the instructions
included
with the replacement
media.
6. Slide filter into cabinet.
7. Replace
filter cabinet
door.
8. Turn on electrical
supply
to furnace.
BLOWER
MOTOR
AND WHEEL
ELECTRICALSHOCK
HAZARD
Failure
to follow
this warning
could
result in personal
injury
or death.
Blower
access door switch
opens
115-v
power
to control.
No
component
operation
can
occur
unless
switch
is closed.
Caution
must be taken when manually
closing
this switch
for
service purposes.
NOTE:
The blower
wheel
should
not be dropped
or bent
as
balance
will be affected.
The
following
steps
should
be
performed
by
a qualified
service
agency.
To ensure
long
life and high
efficiency,
clean
accumulated
dirt
and grease from blower
wheel and motor annually.
The inducer
and blower
motors
are pre-lubricated
and require
no
additional
lubrication.
These
motors
can be
identified
by the
absence
of oil ports on each end of the motor.
Clean blower
motor and wheel as follows:
1. Turn off electrical
supply
to furnace.
2. Remove
outer door.
3. For downflow
or horizontal
furnaces
having
vent pipes
within
the furnace
that pass in front of the blower
access
door:
a. Disconnect
vent connector
from furnace vent elbow.
b. Disconnect
and remove
short piece of vent pipe from
within furnace.
4. Remove
2 screws
from blower
access
door
and remove
blower
access door.
5. All factory
wires
can be left connected,
but field thermo-
stat connections
may need to be disconnected
depending
on their length
and routing.
6. Remove
2 screws
holding
blower
assembly
to blower
deck and slide blower
assembly
out of furnace.
7. Clean blower
wheel
and motor using
a vacuum
with soft
brush
attachment.
Blower
wheel
blades
may be cleaned
with a small paint or flux brush. Do not remove
or disturb
balance
weights
(clips) on blower
wheel blades.
8. Vacuum
any loose dust from blower
housing,
wheel
and
motor.
9. If a greasy
residue
is present
on blower
wheel,
remove
wheel from the blower
housing
and wash it with an appro-
priate degreaser.
To remove
wheel:
NOTE:
Before
disassembly,
mark
blower
motor,
and blower
housing
so motor and each arm is positioned
at the same location
during
reassembly.
a. Disconnect
capacitor
wires and ground
wire attached
to blower
housing.
b. Remove
screws securing
cutoff plate and remove
cutoff plate from housing.
c. Loosen
set screw holding
blower
wheel on motor shaft
(160+/-20
in.-lb,
when reassembling).
d. Remove
bolts holding
motor to blower
housing
and
slide motor out of wheel (40+/-10
in.-lb,
when reas-
sembling).
e. Remove
blower
wheel from housing.
f. Clean wheel and housing.
10. Reassemble
motor
and
blower
by
reversing
steps
9f
through
9a, finishing
with
9a. Be sure to reattach
ground
wire to the blower
housing.
11. Verify
that blower
wheel
is centered
in blower
housing
and set screw contacts
the flat portion
of the motor
shaft.
Loosen
set screw on blower
wheel and reposition
if neces-
sary.
12. Spin the blower
wheel by hand
to verify
that the wheel
does not rub on the housing.
13. Reinstall
blower
assembly
in furnace.
UNIT
DAMAGE
HAZARD
Failure to follow this caution may result in shortened heat
exchanger life.
Heating fan speed(s) MUST be adjusted to provide proper
air temperature
rise as specified
on the rating plate.
Recommended operation is at the nfidpoint of the rise range
or slightly above. Refer to SET TEMPERATURE
RISE
under
START-UP,
ADJUSTMENT,
and
SAFETY
CHECK.
14. Connect
thermostat
leads if previously
disconnected.
15. To check blower
for proper rotation:
a. Turn on electrical
supply.
ELECTRICALSHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
or death.
Blower
access door switch
opens
l15-v
power
to furnace
control.
No component
operation
can occur
unless switch
is
closed.
Exercise
caution
to
avoid
electrical
shock
from
exposed
electrical
components
when manually
closing
this
switch
for service purposes.
b. Manually
close blower
access door switch.
45