Cleaning Heat Exchanger; Igniter Position-Side View - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

NOTE:
If thermostat ternfinals are jumpered
at the time blower
access door
switch
is closed,
blower
will run for 90 sec before
beginning
a heating
or cooling
cycle.
c. Perform
component
self-test
as shown
at the bottom
of the SERVICE
label, located on the front of blower
access door.
d. Verify blower
is rotating
in the correct
direction
16. If furnace
is operating
properly,
RELEASE
BLOWER
ACCESS
DOOR
SWITCH.
Remove
any jumpers
or re-
connect
any
disconnected
thermostat
leads.
Replace
blower
access door.
17. Downflow
or horizontal
furnaces
with vent pipe through
furnace
only:
a. Install and connect
short piece of vent pipe inside fur-
nace to existing
vent,
b. Connect
vent connector
to vent elbow,
18. Reinstall
casing door.
19. Turn
on gas supply
and cycle furnace
through
one com-
plete heating
and cooling
cycle. Verify the furnace temper-
ature rise as shown
in Adjustments
Section.
Adjust
tem-
perature
rise as shown
in Adjustments
Section.
If outdoor
temperature
is below 70 °F, (21 ° C) turn off circuit breaker
to outdoor
unit before
running
furnace
in the cooling
cycle.
Turn
outdoor
circuit
breaker
on after completing
cooling
cycle.
CLEANING
HEAT
EXCHANGER
The
following
steps
should
be
performed
by
a qualified
service
agency:
NOTE:
If the heat exchangers
get a heavy
accumulation
of soot
and carbon,
they should
be replaced
rather
than trying
to clean
them thoroughly.
A heavy build-up
of soot and carbon
indicates
that
a problem
exists
which
needs
to be
corrected,
such
as
improper
adjustment
of manifold
pressure,
insufficient
or poor
quality
combustion
air,
incorrect
size
or damaged
manifold
orifice(s),
improper
gas, or a restricted
heat exchanger.
Action
must be taken to correct
the problem.
If it becomes
necessary
to clean the heat exchangers
because
of
dust or corrosion,
proceed
as follows:
1. Turn OFF gas and electrical
power
to furnace.
2. Remove
outer access door.
3. Disconnect
vent connector
from furnace
vent elbow.
4. For downflow
or horizontal
furnace
having
an internal
vent pipe, remove
internal
vent pipe within
the casing.
5. Disconnect
wires
to the
following
components.
Mark
wires to aid in reconnection
of (be careful
when
discon-
necting
wires from switches
because
damage
may occur):
a. Draft safeguard
switch,
b. Inducer
motor.
c. Pressure
switch(es).
d. Linfit overtemperature
switch,
e. Gas valve.
f. Hot surface igniter.
g. Flame-sensing
electrode,
h. Flame rollout switches,
i. Remove
NOx baffles on low NOx models.
6. Remove
screws
that fasten the collector
box assembly
to
the cell panel. Be careful
not to damage
the collector
box.
Inducer
assembly
and elbow
need
not be removed
from
collector
box.
7. Disconnect
gas line from gas manifold.
8. Remove
the 5 screws
that attach
the burner
assembly
to
the cell panel. The gas valve and individual
burners
need
not be removed
from support
assembly.
NOTE:
Be very
careful
when
removing
burner
assembly
to
avoid
breaking
igniter.
See Fig. 46 and 47 for correct
igniter
location.
9. Using
field-provided
25-caliber
rifle
cleaning
brush,
36-in.
(914
ram)
long,
1/4 in. (6 ram)
diameter
steel
spring
caMe, a variable
speed, reversible
electric
drill, and
vacuum
cleaner, clean cells as follows:
a. Remove
metal screw fitting from wire brush
to allow
insertion
into cable.
b. Insert the twisted
wire end of brush
into end of spring
cable, and crimp tight with crimping
tool or crimp by
striking
with ball-peen
hammer.
TIGHTNESS
IS
VERY IMPORTANT.
NOTE:
The materials
needed
in item 9 can usually
be purchased
at local hardware
stores.
(1) Attach
variaMe-speed,
reversible
drill to the end of spring
caMe (end opposite
brush).
(2) Insert brush
end of cable into the outlet opening
of cell and
slowly
rotate with
drill. DO NOT
force
cable.
Gradually
insert
cable into upper pass of cell. (See Fig. 48.)
(3) Work cable in and out of cell 3 or 4 times to obtain
sufficient
cleaning.
DO NOT pull cable with great force. Reverse
drill and
gradually
work caMe out.
E
9132-
7.1 mm
Fig. 46 - Igniter
Position-Side
View