Troubleshooting Guide - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

START
Is LED status
on?
light
YES
,_ls
there 115V at Lt and L2?
_
YES
I ls there 24V at SEC-1 and SEC-2?
_
YES
Replace furnace
control,
,-,_,_
Is door switch closed?
_
YES
I Isthere
t15V going to switch?
_
YES
l
[ Replace door switch.
v
pause?IS
LED status light blinking rapidly without a
Check for correct line voltage polarity. If units
are twinned,
check for proper low-voltage
(24V) transformer
phasing.
•_
Replace transformer.
"
Is LED status light blinking ON/OFF slowly
w th a comb nat on of short and ong flashes?
I
y
I
/
YES
2 digit number with the first digit determined
_"
Determine
status code, The status code is a
_'
by the number of short flashes and the second
d g t by the number of ong f ashes?
_"
wasG° tofashedsecti°n
below for the status code that
F
I
T
_YES
_Was there a previous status code
other than #tt?
To recall status code briefly remove and reconnect one RED wire from the draft
safeguard
switch to display stored status code,
On RED LED control do not
remove
power or blower access panel before initiating status code recall, You
can also recall the previous status code by momentarily
shorting the TEST/TWIN
terminal to Com24V
terminal
until the LED goes out, LED will flash the status
code of the previous fault or status code #t t (t short and ! long flash) if there
was no previous fault. After the control
repeats the code 4 times, the control
will go through a brief component
test sequence.
The inducer will start and run
for the entire component
test. The HSI, blower motor FAN speed (AMBER
LED
boards only) HEAT speed, and COOL speed will run for t0
t5 seconds
each.
Gas valve and humidifier
will not be turned on.
___
oes the control respond to W, Y1 (if present)
Y/Y2, and G (24V) thermostat
signals?
V
YES
I Run system through a heating or cooling cycle
to check operation.
Status codes are erased
after 72 hours, On RED LED boards stored
status codes can also be erased whenever
(t 15V or 24V) is interrupted.
I Replace furnace
control,
-,_,_,_
Is door switch closed?
I
-"_
Is circuit breaker closed?
p
II
YES
J
Check for continuity in wire from circuit breaker
to furnace,
I
I
I Close circuit breaker and go back to START. I_
I
Check room thermostat
or
I
interconnecting
cable,
I
' NO
___ls
24V present
at W '¢1 (if present)
Y/Y2 or
I
G thermostat
terminals
on the furnace
control?
I
I
,
YES
Disconnect
all the thermostat
wires from the
I
furnace
centre,
I
I
l
___
oes the problem
repeat
when using
a jumper wire?
_
NO
The thermostat
is not compatible
with the
furnace control, Either install a ballast resistor
connect
the Com24V
thermostat
terminal
to
the thermostat,
or replace the thermostat,
NO
A02106a