Service And Maintenance Procedures; Electrical Controls And Wiring; Component Test - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

If status
code recall
is needed,
briefly
remove
then reconnect
one main limit _re
to display
stored status
code.
On RED LED boards do not remove
power or blower
door before
initiating
status
cede recall.
After
status
code recat[ is completed
component
test _[[ cocor.
LED
CODE
STATUS
CONTINUOUS
OFF
- Check
for
115VAC
at L1 and
L2, and
24VAC
at SEC-1
and
SEC-2.
CONTINUOUS
ON
- Control
has
24VAC
power,
RAPID
FLASHING
- Line vottage
(115VAC)
polarity
reversed,
If twinned,
refer
to twinning
kit instructions,
EACH OF THE FOLLOWING
STATUS
CODES IS A ]WO DIGIT
NUMBER WITH THE FI RST DIGIT DETERMI NED BY THE NUMBER OF SHORT FLASHES
AND THE SECOND
DIGIT BY THE NUMBER
OF LONG FLASHES,
11
NO PREVIOUS
CODE
- Stored
status
code
is erased
automatically
after
72 hours,
On
31
PRESSURE
SWITCH
DID NOT
CLOSE
OR REOPENED
- If open
longer
than
five minutes
RED
LED
boards
stored
status
codes
can also
be erased
when
power
inducer
shuts
off for
15 minutes
before
retry,
Check
for:
- Excessive
wind
(115 VAC
or 24 VAC)
to ceetret
is ieterrupted.
- Proper
vent
sizing
- Defective
inducer
motor
12
BLOWER
ON AFTER
POWER
UP
(115 VAC
or 24 VAC)
-Btewer
runs for
90 seconds,
- Low inducer
vettage
(115VAC)
- Defective
pressure
switch
if unit
is powered
up during
a call for heat
(R-W
ctosed)
or R-W
opens
during
blower
- Inadequate
combustion
air supply
- Disconnected
or obstructed
pressure
tubing
on-delay.
- Low inlet
gas
pressure
(if LGPS
used)
- Restricted
vent
13
LIMIT
CIRCUIT
LOCKOUT
- Lockotrl
occurs
if the timit,
draft
safeguard,
flame
rottout,
or
If it opens
during
btower
on-detay
period,
btower
will come
on for the
seIected
btower
blocked
vent
switch
(if used)
is open
longer
than
3 minutes,
off-delay.
- Control
wiii auto
reset after
three
hours.
- Refer
to #33.
33
LIMIT
CIRCUIT
FAULT
- Indicates
a timit,
draft safeguard,
flame
roHout,
or blocked
vent
14
IGNITION
LOCKOUT
- Control
wilt
aLrie-reset
after three
hours,
Refer
to #34.
switch
(if used)
is open,
Blower
wilt
run for 4 minutes
or until open
switch
remakes
21
GAS
HEATING
LOCKOUT
- Control
wilt NOT
auto
reset,
whichever
is longer,
If open toeger
than
3 minutes,
code
changes
to lockout
#13.
Check
for:
- Mis-wired
gas valve
-Defective
control
(valve
reIay)
If open
tess than
3 mieutes
status
code
#33
continues
to flash
untiI
blower
shuts
Off.
22
ABNORMAL
FLAME-PROVING
SIGNAL
- Flame
is proved
while
gas valve
is de-
Ftame
reHeut
switch
and
BVSS
require
manual
reset,
Check
for:
- Restricted
vent
energized.
Inducer
wiii
run until
fault
is cleared.
Check
for:
- Leaky
gas valve
- Proper
vent
sizing
- Loose
blower
wheel.
- Excessive
wind
- Stuck-open
gas valve
- Dirty
filter
or restricted
duct
system.
23
PRESSURE
SWITCH
DID NOT
OPEN
Check
for:
- Defective
blower
motor
or
capacitor.
- Defective
switch
or connections.
- Obstructed
pressure
tubing,
- Pressure
switch
stuck
closed,
- Inadequate
combustion
air supply
(Flame
Roll-out
Switch
open),
24
SECONDARY
VOLTAGE
FUSE
IS OPEN
Check
for:
34
IGNITION
PROVING
FAILURE
- Control
wilt try three
more
times
before
lockout
#14
- Short
circuit
in secondary
voltage
(24VAC)
wiring,
occurs,
If flame
signal
test during
blower
on-delay
period,
blower
wilt
come
on for the
selected
blower
eff-dalay.
Check
for:
- Ftame
sensor
must
net be grounded
- Oxide
buildup
oe flame
sensor
(clean
with fine
steel
wool).
- Proper
flame
sense
microamps
(.5 microamps
D.C.
mie.,
4.0
- 6.0 nominal).
- Gas
valve
defective
or gas
valve
turned
off
- Manual
valve
shut-off
- Defective
Hot Surface
Ignitor
- Control
ground
continuity
- Low intet
gas
pressure
- Inadequate
flame
carryover
or rough
ignition
- Green/Yellow
wire
MUST
be connected
to furnace
sheet
metal
45
CONTROL
CIRCUITRY
LOCKOUT
Auto-reset
after
one
hour
lockout
due
to;
- Gas
valve
relay
stuck
open
- Ftame
sense
circuit
faiIure
- Software
check
error
Reset
power
to clear
lockout,
Replace
control
if status
code
repeats.
COMPONENT
TEST
To
initiate
the
component
test
sequence,
shut
OFF the
room
thermostat
or disconnect
the
"R"
I
I
thermostat
lead.
Briefly
short
the TEST/TWIN
terminal
to the
"Corn
24V"
terminal.
Status
LED
wiii
flash
code
and then
turn ON the
inducer
motor.
The
inducer
motor
wilt
rue for the
entire
I
component
test.
The hot surface
ignitor,
blower
motor
fan speed
(oe
AMBER
LED
boards
only)
Newer
motor-heat
speed,
and
blower
motor-coot
speed
wilt
be turned
ON for
10-15
I
seconds
each.
Gas Valve
and
Humidifier
wilt
not be turned
on.
_
327596-101
REV. B
A04223
Fig. 45 -
Service
Label
SERVICE
AND MAINTENANCE
PROCEDURES
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
death and/or property
damage.
The
ability
to properly
perform
maintenance
on this
equipment
requires
certain
knowledge,
mechanical
skills, tools, and equipment.
If you do not possess
these,
do not
attempt
to perform
any maintenance
on this
equipment
other than those procedures
recommended
in
the User's
Manual.
ELECTRICAL
SHOCK,
FIRE OR EXPLOSION
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury or death, or property
damage.
Before
servicing,
disconnect
all electrical
power
and install
lockout
tag
to
furnace.
Verify
proper
operation
after
servicing.
ELECTRICAL
OPERATION
HAZARD
Failure
to follow
this caution
may
result
in
improper
furnace
operation.
Label
all wires
prior
to
disconnection
when
servicing
controls.
Wiring
errors can cause
improper
and dangerous
operation.
ENVIRONMENTAL
HAZARD
Failure to follow this caution may result in environmental
pollution.
Remove and recycle all components or materials (i.e. oil,
refrigerant, et.) before unit final disposal.
Step 1 reintroduction
GENERAL
These instructions
are written
as if the furnace
is installed
in an
upflow
application.
An upflow
furnace
application
is where
the
blower
is located
below
the combustion
and controls
section
of
the furnace,
and conditioned
air is discharged
upward.
Since this
furnace can be installed in any of the 4 positions shown in Fig. 4,
you
must
revise
your
orientation
to component
location
accordingly.
ELECTRICAL
CONTROLS
AND WIRING
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury or death.
Before
installing,
modifying,
or servicing
system,
main
electrical
disconnect
switch
must be in the OFF position
and
install a lockout
tag. There may be more than one electrical
supply
to the furnace.
Check
accessories
and cooling
unit
for additional
electrical supplies
that must be shut off during
furnace
servicing.
Lockout
and tag switch
with
a suitable
warning
label.
Verify proper operation
after servicing.
The electrical ground and polarity for 115-v wiring must be
properly maintained. Refer to Fig. 26 for field wiring information
and to Fig. 41 for furnace wiring information.
NOTE:
If the polarity is not correct, the STATUS LED on the
control will flash rapidly and prevent the furnace from heating.
43