Minimum Vent Heights Table; Upflow Application - Vent Elbow Up/Right - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

Table
10--Minimum
Vent
Heights
Caution!!
for the
following
applications,
use the
minimum
vertical
vent
heights
as specified
below.
For
all other
applications,
follow
exclusively
the national
fuel
gas
code.
MiNiMUM
VENT
MiNiMUM
VERTICAL
VENT
FURNACE
VENT
FURNACE
DIAMETER
HEIGHT
ORIENTATION
ORIENTATION
iNPUT
(BTUH/HR)
IN. (rnm)*
FT. (M)**
Vent
elbow
left, then
154,000
132,000
5 (127)
12 (3.6)
Downfiow
up Fig. 32
110,000(036/-
12 only)
Vent elbow
right,
154,000
Horizontal
Left
then
up Fig. 35
132,000
5 (127)
7 (.65)
Vent
Elbow
up
154,000
Horizontal
Left
Fig.
36
132,000
5 (127)
7 (,65)
Horizontal
Left
Vent elbow
right
Fig. 37
154,000
5 (127)
7 (.65)
Vent elbow
up then
110,000
Downfiow
left Fig. 30
(036/-12
only)
5 (127)
10 (3.0)
Vent elbow
up, then
110,000
Downfiow
right
Fig. 33
(036/-12
only)
5 (127)
10 (3.0)
4 in. (102 mm) inside casino or vent guard
** Including 4 in. (102 mm) vent section (s)
NOTE: All vent configurations
must also meet National Fuel Gas Code (NFGC) venting requirements
NOTE: For all unlisted vent configurations,
refer to National Fuel Gas Code (NFGC) venting
requirements.
_
o_
SEE NOTES:
1,2,4,7,8,9
on the page following
these figures
Fig. 28 -
Upflow
Application-Vent
Elbow
Up
A03208
SEE NOTES: 1,2,3,4,7,8,9
on the pages following
these figures
A03209
Fig.
29
-
Upflow
Application-Vent
Elbow
Right
29