Services - GE Security SymSafe User Manual

4, 8, or 16-channel digital video recorder
Table of Contents

Advertisement

64
SymSafe/SymSafe Pro
User Manual
SymNav software also connects to these products using UDP/TCP protocols depending on what is configured.
The default setting is UDP. Changing from UDP to TCP or TCP to UDP is accomplished through the SymNav
software application.
SymNav software can connect to a maximum of 4 video streams. This can be 4 separate SymSafe units with 1
stream each or 2 SymSafe's with 2 streams each.

Services

Use this menu to define the parameters of the networks services.
administrator or IT professional to configure these settings
Figure 42. The Network/Services menu
Table 28. The Network/Services menu options
Menu Options
HTTP Port
NTP Server 1 IP Address
NTP Server 2 IP Address
Interval
Name Service
Hostname
Settings
80 is the default. Select from 0 to 65535. To disable SymBrowser access set the port to 0.
IP Address
IP address
Never, Once per Hour, Twice per Day, Once per Day
Disabled, DynDNS, TZO, GnuDIP
The default hostname is the unit's serial number.