Disassembly Procedures
!
NOTE: Teeth On Journal Lock Into The Tumbler To
Prevent Rotation.
LEFT
Note: Arrow Direction for the Left and Right Timing
Marks. The point of the triangle on the right
Tumbler must align between the 2 points of the
left Tumbler along the base of the triangle. Any
other configuration such as the two flat sides
aligned, or the points of the triangle facing each
other, indicates two left or right side Tumblers.
Replace one of the Tumblers.
Identify left and right Tumbler location by the "L"
and "R" visible in the bottom of the Spinner when
the Tumbler is removed.
©2003 Maytag Appliances Company
WARNING
BACK
RIGHT
16022808 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
Left Timing Mark

Tumbler Bearing Removal

1. Disconnect power supply to unit.
2. Lift lid.
3. Remove Tumbler.
4. Remove Torx™ screws 3 each side.
LEFT
Right Timing Mark
BACK
RIGHT