Hose Reversal Detection And Correction; Torque Specifications; Tub Displacement Sensor Diagnostics - Maytag Neptune TL FAV6800A Service

Hide thumbs Also See for Neptune TL FAV6800A:
Table of Contents

Advertisement

Troubleshooting Procedures
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.
and resume normal operations. Pressing the Off key will
completely exit Service Mode. If a cycle is running,
cancel the cycle. Pressing the Start/Pause key while
running a test will pause the individual test, while
remaining in Service Mode. A power loss during Service
Mode will cancel this mode.

Hose Reversal Detection and Correction

The washing machine has diagnostic features that
determine if the hoses are reversed on the first
complete cycle after power up. The control board
monitors water temperatures during the wash cycle.
The control system is capable of detecting hot and cold
water intake hose reversal and will change the fill
temperature as necessary after the first cycle.
The control system stores and retains hot and cold
water intake hose reversal information through a power-
down.
The system reverts to factory defaults for the cold and
hot water valves and cancels hose reversal detection if
a diagnostic code 28 has been logged in a cycle.
See "Wrong Water Temperature" in the trouble
shooting tips, at the beginning of this document for more
information.

Torque Specifications

©2003 Maytag Appliances Company
!
WARNING
Spinner Support Shaft Nut 64-80 ft. lbs. Special
wrench required.

Tub Displacement Sensor Diagnostics

CAUTION: Do not perform continuity check directly on
Displacement Sensor due to the potential for damaging
the microprocessor chip in the sensor.
1.
Enter the Service Mode by pressing the Help and
Back keys for three seconds.
Press System Check on the display
2.
3.
Push tub to back right corner so sensor extends
beyond the #2 mark molded on slider. Display will
show "tub unbalance".
Pulley clutch Bolt
96 in. lbs.
4.
Pull tub to front left corner and push down so
sensor collapses to before the #1 mark molded on
slider. Display will show "tub unbalance".
NOTE: Moving the tube midway between mark #1 and
Clamp Ring 15-
20 ft. lbs.
16022808 Rev. 0
#2 Mark
mark #2 represents normal operation. Display
will show "no unbalance".
Tub
Displacement
Sensor
#1 Mark
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents