64
Connection via
Cooker Control Circuit 2,5 mm²
It is necessary that you install a double pole switch between the oven and the
electricity supply (mains), with a minimum gap of 3 mm between the switch con-
tacts and of a type suitable for the required load in compliance with the current
regulations.
The switch must not break the yellow and green earth cable at any point.
After installation and connecting, the cable must be placed so that it cannot at any
point reach a temperature of more than 50°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic instal-
lation can support the load; and that the power supply is properly earthed.
The manufacturer declines any responsibility should these safety measures
not be carried out.

Installation instructions

CAUTION!
The new appliance may only be installed and connected by a qualified installation
engineer. Please comply with this instruction. If you do not, any damage resulting
is not covered by the warranty.
To prevent risk of injury, damaged connection cables must be replaced by our
Customer Care Department or a designated specialist

Safety information for the installation engineer

• The electrical installation is provided with a device to enable the appliance to be
cut off from the mains with with a minimum 3 mm all-pole contact separation.
Suitable separation devices include e. g. cut-outs, fuses (screw fuses are to be
taken out of the holder), RCDs and contactors.
• The site must provide a connection to the electrical supply by means of a socket
that is accessible and outside the configuration space.
• Anti-shock protection must be provided by the installation.
• The built-in unit must meet the stability requirements of DIN 68930.
Min. size Cable/flex
Cable/flex type
PVC/PVC twin and
earth
Fuse
min: 15 A
max: 20 A