Log Utilities; Function Description - Toshiba Tecra M4 Maintenance Manual

Hide thumbs Also See for Tecra M4:
Table of Contents

Advertisement

3.22 Log Utilities

3.22

Log Utilities

3.22.1 Function Description

This function logs error information generated while a test is in progress and stores the
results in RAM. This function can store data on a floppy disk, or output the data to a printer
or the display.
The error information is displayed in the following order:
1. Error count (CNT)
2. Test name, Subtest number (TS-No)
3. Pass count (PASS)
4. Error status (STS)
5. FDD/HDD or memory address (ADDR)
6. Write data (WD)
7. Read data (RD)
8. HDC status (HSTS)
9. Error status name (ERROR STATUS NAME)
If the power switch is turned off, the error information will be lost.
TECRA M4 Maintenance Manual (960-521)
[CONFIDENTIAL]
3 Tests and Diagnostics
3-49

Advertisement

Table of Contents
loading

Table of Contents