4.32 Fluorescent lamp
4 Replacement Procedure
Fasten screws of the PCB and bezel
1. Fasten four screws. ((1) in the bellow figure)
N
・
CAUTION: 1. The tightening torque must be 0.176
m (1.8kgf
cm) for all the screws.
2. Use an insert bit of point size 0 for the Philips screwdrivers.
(1)
(1)
(1)
(1)
Figure 4-58 Replacing 14.1 Inch TMD fluorescent lamp (10)
TECRA M4 Maintenance Manual (960-521)
[CONFIDENTIAL]
4-87