Procedure 1; Power Supply Icon Check - Toshiba Tecra M4 Maintenance Manual

Hide thumbs Also See for Tecra M4:
Table of Contents

Advertisement

2.3 Power Supply Troubleshooting

Procedure 1

Power Supply Icon Check

The following two icons indicate the power supply status:
Battery icon
DC IN icon
The power supply controller uses the power supply status with the Battery icon and the DC IN
icon as listed in the tables below.
Battery icon
Lights orange
Lights green
Blinks orange
(even intervals)
Flashes orange
(at being switched on)
Doesn't light
DC IN icon
Lights green
Blinks orange
Doesn't light
*1 When the power supply controller detects a malfunction, the DC IN icon blinks
orange. It shows an error code.
TECRA M4 Maintenance Manual (960-521)
Table 2-1 Battery icon
Power supply status
Battery is charged and the external DC is input. It has no relation
with ON/OFF of the system power.
Battery is fully charged and the external DC is input. It has no
relation with ON/OFF of the system power.
The battery level is low while the system power is ON.
The battery level is low and the power is turned on only with the
battery.
Any condition other than those above.
Table 2-2 DC IN icon
Power supply status
DC power is being supplied from the AC adapter.
Power supply malfunction
Any condition other than those above.
[CONFIDENTIAL]
* 1
2 Troubleshooting
2-7