The preceding messages are not errors and can be safely ignored.

Fixing test partner connection for SSL connections

If the Tools/Test partner Connection fails when a Gateway https URL is selected,
the following error message displays:
Exception during http POST-: null
This error can occur when using either the POST or GET commands.
The Console Tools/Test partner Connection only works with HTTP.

Fixing errors BCGEDIEV0O56 and BCG210001

About this task
An EDI transformation map can fail with the Check Channel error and errors
BCGEDIEV0O56 and BCG210001 on Oracle systems and produce the warning
event:
Warning BCGEDIEV0O56 Event "Translation Table Lookup Warning":
A translation table lookup returned no entry while deenveloping a message.
Next: "Check Channel Error - Channel lookup failed. Not enough channel info
This error occurs when the Oracle database is not created with the Unicode
character set but is incorrectly set to Windows 1252 or similar non-Unicode code
page.
To verify the character set on Oracle:
1. Connect to the oracle database.
2. Select NLS_CHARACTERSET from v$nls_parameters.
3. The value returned should be AL32UTF8.
There is not a direct way of modifying the character set of the database once it has
been created. The solution is to re-create the database with the database character
set and the national character set as Unicode.
Fixing ORA-00988 error
This error occurs because of an Oracle limitation. If a password beginning with a
number is not entered within quotation marks, then you see:
ORA-00988: missing or invalid password(s)
To resolve this error enter any password that begins with a number for an Oracle
database in quotation marks (for example, "123456ABC") in the WebSphere Partner
Gateway installation panels.

Configuring Content-Types attribute for the fixed workflow handlers

About this task
WebSphere Partner Gateway might fail to route an EDI document received through
HTTP. An EDI document is sent with the content-type as text/plain and you
should ensure that the Fixed Workflow handlers are configured correctly.
172
IBM WebSphere Partner Gateway Enterprise and Advanced Editions: Administration Guide
Verify this on your Oracle systems.