Documents Routed Twice When Network Is Lost Or Document Manager Server Shutdown Abruptly; 0A1 Generated With Data Validation Errors; Edi Reports Export The First 1000 Records Only; Console Does Not Start After A Server Restart - IBM E02HRLL-G - WebSphere Partner Gateway Express Administration Manual

Administration guide
Table of Contents

Advertisement

Documents routed twice when network is lost or document manager
server shutdown abruptly
If the system running your Document Manager abruptly loses its network
connection or shuts down while processing a document that has not yet had its
status updated, the document may be sent twice. The system administrator should
take steps to avoid unexpected shutdowns or abnormal outages of the document
manager workstation.

0A1 generated with data validation errors

About this task
The 0A1 specification mandates that GlobalSupplyChainCode be present in the
XML. If the incoming 3A7 does not contain this value, it must be added as an
attribute to the 0A1. GlobalSupplyChainCode must be either in the 3A7 document
or added as attribute to 0A1 in Document Definition.
To add the attribute:
1. Click Hub Admin > Hub Configuration > Document Definition. The Console
2. Click Package: RNIF > Protocol: Rosettanet > DocumentType: 0A1, and click
3. If the Global Supply Chain Code attribute is not there, click Add Attributes to
4. Select a value from the list.
5. Click Save.

EDI reports export the first 1000 records only

The export function of the 2 EDI Reports FA Overdue and Rejected Transactions
exports the first 1000 records only in order to minimize unexpected system
shutdowns because of memory overflow issues. If the number of records to export
from the reports is over 1000, export the records directly from the related database
view: LG_EDI_Overdue_FA_VW or LG_EDI_Rejected_Tx_VW.

Console does not start after a server restart

If you have installed WebSphere Partner Gateway, started the console server and
logged into the console successfully, but find that once you have restarted the
server your console does not display and runs in a loop, ensure that your tracing
level is not set to "WAS.*=finest". This setting is used to perform the finest logging
of all WebSphere Application Server related classes. The default connection time
out for the WebSphere Partner Gateway console to start is set at 180 seconds and if
the WebSphere Application Server tracing level is set to "finest" the processing time
it takes to log all of that information along with making the requisite database
connections causes the system to time out. Alter the setting and restart the console
server.
Note: Setting the tracing level to "finest" can affect system performance.
displays the Manage Document Definitions window.
the Edit attribute values icon.
add it.
Chapter 17. Troubleshooting