Energy Efficient Ethernet (Eee) Commands; Green-Mode Eee - NETGEAR ProSAFE M7100-24X Reference Manual

Prosafe m7100 managed switches command-line interface (cli) reference manual
Hide thumbs Also See for ProSAFE M7100-24X:
Table of Contents

Advertisement

ProSAFE M7100 Managed Switches

Energy Efficient Ethernet (EEE) Commands

Energy Efficient Ethernet (EEE) combines MAC with ports that support operation in a Low-Power
Mode. This feature is defined by the IEEE 802.3az Energy Efficient Ethernet Task Force. Lower
Power Mode enables both send and receive sides of a link to disable some port functionality to
save power when the port is lightly loaded. Transition to Low-Power Mode does not change the
link status. Frames in transit are not dropped or corrupted during transition to and from
Low-Power Mode. This transition time is transparent to upper layer protocols and applications.
EEE operation is subject to the following conditions:
Autonegotiation must be enabled to use any of the EEE modes. EEE mode is disabled
automatically when autonegotiation is disabled.
Enabling or Disabling EEE mode causes the port link to flap once as EEE capability needs to be
advertised. This restarts autonegotiation.
EEE must be disabled while running hardware or software cable diagnostics.
Combo (Combination) ports: Combo ports support both copper and fiber media. EEE mode
only applies to copper media. If Energy Detect mode is configured on a combination port, it
will only function when a copper media is active. EEE LPI statistics are only collected if a
copper media is used on the port. If the media on a port changes from copper to fiber while
EEE is enabled, LPI statistics collection stops until the media changes back to copper. The
show green-mode command and show green-mode eee-lpi-history
interface command display updated LPI statistics only if the medium is copper.

green-mode eee

This command enables EEE low-power idle mode on an interface or on all interfaces. It allows
both send and receive sides of a link to disable some functionality for power savings when the
port is lightly loaded. Transition to Low-Power Mode does not change the link status. Frames in
transit are not dropped or corrupted in transition to and from Low-Power Mode.
Default
Disabled
Format
green-mode eee
Mode
Interface Config
Interface Range Config
no green-mode eee
This command disables EEE.
Format
no green-mode eee
Mode
Interface Config
Interface Range Config
Green Ethernet Commands