Using Service Walk Test; Using Default Text; Keypad Setup Menu - Bosch D1265 Owner's Manual

Touchscreen keypad
Hide thumbs Also See for D1265:
Table of Contents

Advertisement

Using Service Walk Test

The Service Walk Test function is only
available in the Service Menu for
D9412GV3/D9412GV2 control panels. If
the control panel model is
D7212GV3/D7212GV2, you must enable
the Service Walk Test on the Function list
for the keypad through the control panel's
programming.
1. When the display shows ### points remain to
be tested you can begin. (### is the number of
points).
If you know the point number, you can
enter it by pressing its number button and
then the ENTER button.
The display changes to show the point
that was entered. If the point is invalid the
message "Invalid Point" or "This is not a
valid walk point" appears.
Test each point by first opening and then
closing the door or window or other detection
device.
Check the display after testing each point. For
interior points, walking past the device once is
sufficient. If any point will not test correctly,
contact your security company for service.
2. During the Walk Test you might want to refer
to the points that remain untested by pressing
the View untested pts button.
The display shows ### pts untested.
Press the Point information button to see
information about specific points that have not
yet been tested.
The display changes to show the information
for that point.
Move through this list by pressing the Next
Point button.
Press the Exit button to return to the ###
points remain to be tested before continuing
the Service Walk Test.
3. When all points have been tested, 0 points
remain to be tested is shown.
Press the Exit button.
The display momentarily shows All points
have been tested before returning to idle text.
Bosch Security Systems, Inc. | 9/10 | F01U169130-02
D1265 | Owner's Manual | Part III: Advanced Commands

Using Default Text

This function allows the current state of the area for 3
sec before returning to idle text.
1. Press the Default Text button to display the
current state of the area.
2. The current state of the area is shown for 3 sec
before returning to idle text.

Keypad Setup Menu

The Keypad Setup menu is accessible at anytime
from any keypad menu. To start the menu, press and
hold the 0 button for at least 5 sec.
The adjustable functions that are available in this menu
are:
Set the keypad's SDI Bus address
Adjust the keypad volume and display
brightness
Turn the button click tone on or off
Set the screen on time
Use the up and down buttons for each function to
change the setting for the options:
Keypad Address, SDI bus address
Keypad Volume. Applies to low priority tones
only
Button Click. Key press acknowledgement
Brightness
Screen On Time. Time in minutes before
power saving mode activates.
Press Save to save your changes when finished. The
display returns to idle text. Press Back to exit the
menu.