Environmental And Power Requirements; Table 2.3 Environmental And Power Requirements - Fujitsu MCM3064AP Product Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

Specifications

2.1.3 Environmental and power requirements

Table 2.3 lists the environmental and power requirements.
Table 2.3 Environmental and power requirements (1 of 2)
Item
Power
Average
requirements
Power
Ready
consumption
Random seek, read or write
(Average)
Power save
mode
Outer
With panel
dimensions
(W
D
H)
Without panel
K
K
Weight
Environmental
Operating
requirements
Idle
Transport
Installation
Tilt angle
2-4
+5 VDC±5% 1.2 A (2.7 A max) (*1)
Ripple requirement 100mV pp (DC-1 MHz)
3.9 W (typ) (*2)
5.8 W (typ) (*2)
Pre-idle mode
3.9 W (typ) (*2)
Idle mode
2.0 W (typ) (*2)
Standby mode
1.2 W (typ) (*2)
Sleep mode
1.2 W (typ) (*2)
101.6
1 50.0
K
101.6
1 48.4
K
410 g (with panel)
Temperature: 5 to 45°C (gradient 15°C /h or less)
Relative humidity: 10 to 85% (No condensation)
Maximum wet bulb temperature: 29°C or lower
Temperature: 0 to 50°C
Relative humidity: 10 to 85% (No condensation)
Maximum wet bulb temperature: 36°C or lower
Temperature: –40 to 60°C (24 hours or less)
Temperature: –20 to 60°C (24 hours or more)
Relative humidity: 5 to 90% (No condensation)
Maximum wet bulb temperature: 41°C or lower
–5° to +10° (*3)
Specification
2 5.4 mm
K
2 5.4 mm
K
(*3)
C156-E227-01EN