Table 4.118 Register/Pio Data Transfer Timing Parameters - Fujitsu MCM3064AP Product Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

Host Interface

Table 4.118 Register/PIO data transfer timing parameters

Symbol
t0
Cycle time
t1
DIOR-/DIOW- setup time
t2
DIOR-/DIOW- pulse width
t2i
DIOR-/DIOW- recovery time
t3
DIOW- data setup time
t4
DIOW- data hold time
t5
DIOR- data setup time
t6
DIOR- data hold time
t6Z
DIOR- data High –Z time
t7
From address decided to IOCS16- asserted
t8
From address decided to IOCS16- released
t9
DIOR-DIOW- to address valid hold time
tA
IORDY setup time
tB
IORDY pulse width
tRd
Read data valid to IORDY active
4-86
Timing parameter
min
max
(Units: ns)
(Units: ns)
120
-
25
-
70
-
25
-
20
-
10
-
20
-
5
-
-
30
-
30
-
30
10
-
-
35
-
1250
0
-
Condition
At mode 4,
no wait
PIO flow
control
transfer mode
PIO flow
control
transfer mode
C156-E227-01EN