3.8 Cable Connections

Use the following cables to connect the optical disk drive to the system. See
Section 3.4, "Cable Connections" for details on the connector positions and cable
connection requirements.
Power supply cable
AT interface cable
The general procedure for and precautions on connecting cables are given below.
Be extra careful regarding the insertion direction of each cable connector.
1) Connect the power cable.
2) Connect the AT interface cable.
3) After inserting the connector of a cable, hold the cable properly so that it
neither touches a part on the device and PC board unit nor prevent the cooling
air from flowing in the system cabinet.

3.9 Post-installation Operation Check and Preparation for Use

3.9.1 Initial operation check

This section provides the operation check procedures after power-on.
(1) Initial operation upon power-on
When the power is turned on, the drive starts initial self-diagnostics. The
LED on the front panel is on for 1 second during initial self-diagnostics.
If an error is detected during initial self-diagnostics, the LED on the front
panel blinks. If the initial self-diagnostics normally terminates, the LED goes
off.
If the power is turned on with no cartridge inserted, the eject motor
automatically turns once.
3-24
Device damage:
-
Make sure that the system power is off.
-
Do not connect or disconnect any cable while the drive power is on
C156-E227-01EN