Table 2.3 Environmental and power requirements (2 of 2)
Item
Vibration/
Operating
shock
Idle
No cartridge, power ON
Transport
Altitude
Operating
Idle
Ambient
Air flow
cleanliness
Air purity
*1
*2
*3
Note:
1.
2.
3.

2.1.4 Error rate

Data blocks to be accessed should be evenly distributed on the disk. Errors due to
disk defects are not included.
(1) Bit error rate after ECC processing
The error rate after ECC processing must be 10-12 or less. An optical disk whose
raw error rate is 10-4 or less should be used.
(2) Positioning error rate
The positioning error rate must be 10-6 or less (with retry).
C156-E227-01EN
Shock 19.6 m/s
Shock
Shock 490 m/s
Requirement: Packing specifications specified by Fujitsu
3,000 m (10,000 ft) or less
12,000 m (40,000 ft) or less
Not required
General office environment or better
(dust particle level: Class 5 million or less particle level)
During random seek or read/write but excluding pulse waveform at 500 s
or less
Average value at an ambient temperature of 25°C and a voltage of 5 V
The performance is specified at an ambient temperature of 25°C and level
placement at 0°.
The current limiter value on the power supply must not exceed 5 A.
The specifications for during transport are under the packaging conditions
specified by Fujitsu.
Note that, concerning the power requirements, a voltage drop may occur
depending on the power cable in use.
2.1 Specifications of Optical Disk Drives
Specification
2
3.92 m/s
{0.4 G} (5 to 500 Hz, Sine Sweep)
2
{2 G}
(10 ms, Half Sine Pulse)
2
9.8 m/s
{1.0 G} (5 to 500 Hz, Sine Sweep)
2
49 m/s
{5 G}
(10 ms, Half Sine Pulse)
2
{50 G}
(10 ms, Half Sine Pulse)
2-5