3.5 Power Requirements

Copper wire suitable for at least 167°F (75°C) MUST be used for power connections.
MODEL
VOLTAGE
KSCFH18E
KSCFH18E
The electrical power supply for this appliance MUST be the same as indicated on
the rating plate located on the inside of the fryer door.
All wiring connections for this appliance MUST be made in accordance with the
wiring diagrams furnished with the equipment. Wiring diagrams are located on the
3.5 Operating Switches
A. Fryer with KFC-1 Computer
This fryer/filter system is equipped with a drain valve safety switch and a frypot float-switch on
each of the two-batteried fryers. Drain-valve safety switches de-energize the fryer heating
elements during the filter process, thus providing an additional safety feature. Always leave the
computer on when filtering.
The KFC-1 computer monitors filter operations. The computer logs the number of times the
fryer has been filtered, and will lock out when a preset number is reached. The drain valve must
be opened and closed, and the frypot refilled with oil/shortening before the KFC-1 computer will
allow a cook cycle (after filtering).
See the KFC-1 Computer User's Manual for detailed information.
B. Other Fryer/Filter Switches
1. Fryer Power Switch (Computer): The fryer's power is turned on and off with the computer.
See computer manual for more detail.
CHAPTER 3: INSTALLATION INSTRUCTIONS
PHASE
WIRE
SERVICE
208
3
240
3
inside of the fryer door.
DANGER
MIN.
SIZE
2
AWG
(mm
3
6
(16)
3
6
(16)
DANGER
DANGER
3-4
AMPS PER LEG
)
L1
L2
50
50
43
43
L3
50
43