8.2 Fryer Troubleshooting (cont.)
Actual frypot temperature
differs
7.2.2
setpoint temperature.
7.2 Fryer Troubleshooting (cont.)
Actual frypot temperature
7.2.2
differs from computer
(cont.)
setpoint temperature.
CHAPTER 7: TROUBLESHOOTING
1. Turn fryer "ON".
from
computer
2. Select a product number and allow the
3. Place a thermometer within 1-inch (2.5-
4. Press the computer temperature button
5. The thermometer temperature should be
6. Contact your authorized Frymaster
7-3
fryer to heat for approximately 30
minutes
to
stabilize
temperature.
cm) of the temperature probe mounted
on the heating elements.
to check frypot temperature. Press the
computer temperature button twice to
view setpoint temperature for the
product number chosen.
within ±10°F (±5°C) of the computer
display temperature. If the results are:
Yes- System is maintaining temperature
properly.
No- The computer probe circuit may be
faulty.
service agent if any of the following
occurs during this test:
a. Computer probe circuit is suspect.
shortening