Frymaster FLYMASTER KSCFH18E Installation & Operation Manual page 17

Cool zone series electric fryers
Table of Contents

Advertisement

KSCFH18E COOL ZONE SERIES ELECTRIC FRYERS
3.5 Operating Switches (cont.)
4.
Filter Pump Reset: Located under the left
control panel of the fryer battery. This
switch resets the UFF filter pump motor.
5.
Manual Filter Override Switch: Located
under the left fryer control panel of the
fryer battery. This toggle switch allows
the operator to manually operate the UFF
filter if a problem develops with the auto
functions.
3.6 Drain and Oil-Return Handles
1.
Drain Valve Handle (Red). Pull to open.
The drain valve handle should be closed
at all times except when draining and/or
filtering the fryer.
2.
Oil Return Valve Handle (Yellow). Pull
the oil return valve handle to open the oil
return valve for the frypot being filtered.
The filter pump activates when this
handle is pulled. Pull the yellow handle
only when filtering. Pushing the yellow
handle in closes the oil return valve and
deactivates the pump motor.
If the filter pump safety switch repeatedly trips, do not continue to reset. A potential
safety hazard exists. Contact an authorized service technician for troubleshooting.
CHAPTER 3: INSTALLATION INSTRUCTIONS
Filter pump reset switch
Drain valve handle.
WARNING
3-6
Manual filter override switch
Oil return valve handle.

Advertisement